5444 (< 30100) FETMM
(5/70)
B-1
Appendix B. World Trade or Domestic Differences
B.1 POWER REQUIREMENTS
The 5444 is available for use with either a SOHz or a 60
Hz power supply. The machine index card states the
power supply to which the machine has been built.
B.1.1 50 Hz Power Supply
The 50 Hz power supply is as follows:
220/235Vac ±10%, single phase.
Peak current (starting): 3.5 amperes.
Average current: 1.0 ampere.
B.1.2 60 Hz Power Supply
The 60 Hz power supply is as follows:
208/230V ac
±
10%, single phase.
Peak current (starting): 3.5 amperes.
Average current: 1.0 ampere.
B.2 COMPONENTS
When the power supply frequency or voltage is changed,
change the components listed in Figure B-1.
Power Supply Changed
Component to be Changed
Frequency and voltage
1.
Brush motor (see 4.3.3)
2. Drive motor and drive motor
pulley (see 4.2.6)
Voltage only
Drive motor (see 4.2.6)
Figure B-1. Power Supply Change - Components to be Changed
[07569)