  • Page 1: Table Of Contents

    Continuous level measurement Continuous level measurement ® ® NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Contents page About this document For your safety Product description Technical data Mounting...
  • Page 2: About This Document

    ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual About this document Function This instruction provides all the information you need for mounting, connection and setup as well as important instructions for maintenance, fault rectification, safety and the exchange of parts.
  • Page 3: For Your Safety

    ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual For your safety Authorised personnel All operations described in this documentation must be car- ried out only by trained and authorized personnel.
  • Page 4 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual For your safety Conformity The device complies with the legal requirements of the appli- cable country-specific directives or technical regulations.
  • Page 5 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual For your safety Installation and operation in the USA and Canada This information is only valid for USA and Canada.
  • Page 6: Product Description

    ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Product description Configuration The scope of delivery encompasses: Scope of delivery •...
  • Page 7 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Product description Fig. 1: Level measurement Sensor reference plane (seal surface of the process fitting) d Distance to the level h Height - Level...
  • Page 8 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Product description Fig. 2: Interface measurement Sensor reference plane (seal surface of the process fitting) d1 Distance to the interface d2 Distance to the level...
  • Page 9 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Product description • Gas phase - dependent on the application, gas phase does not always exist (d2 = 0) The instrument is always preset to the application "Level Output signal...
  • Page 10 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Product description Accessories The instructions for the listed accessories can be found in the download area on our homepage.
  • Page 11: Technical Data

    ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Technical data Technical data Note for approved instruments The technical data in the respective safety instructions which are included in delivery are valid for approved instruments (e.g.
  • Page 12 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Technical data Ʋ Cable gland PA, stainless steel, brass Ʋ...
  • Page 13 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Technical data Ʋ Centering weight ø 75 mm 825 g (26.52 oz) (2.953 in) Ʋ...
  • Page 14 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Technical data Output variable Output signal 4 … 20 mA/HART Range of the output signal 3.8 … 20.5 mA/HART (default setting)
  • Page 15 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Technical data Fault signal, current output (adjust- ≥ 21.0 mA, ≤ 3.6 mA able) In order to detect the rarely occurring hardware...
  • Page 16 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Technical data Fig. 3: Measuring ranges - NivoGuide 8200 Reference plane Probe length L Measuring range (default setting refers to the measuring range in water)
  • Page 17 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Technical data Typical deviation - Level measure- See following diagrams ment 1)2)
  • Page 18 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Technical data 15 mm (0.591 ") 2 mm (0.079 ")
  • Page 19 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Technical data 25 mm (0.984") 2 mm (0.079") -2 mm (-0.079")
  • Page 20 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Technical data Influence of the superimposed gas and pressure on measurement accuracy The propagation speed of the radar impulses in gas or vapour above the medium is reduced by high pressure.
  • Page 21 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Technical data The measurement error through the process conditions in the specified pressure and temperature range is < 1 %.
  • Page 22 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Technical data 80°C / 176°F 60°C / 140°F 50°C / 122°F 40°C / 104°F 0°C / 32°F...
  • Page 23 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Technical data 400 bar (5800 psig) 380 bar (5510 psig) 350 bar...
  • Page 24 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Technical data Material ca- Material Cable diameter ble gland seal insert 4.5 … 8.5 mm...
  • Page 25 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Technical data Additional output parameter - Electronics temperature Range -40 … +85 °C (-40 … +185 °F) Resolution...
  • Page 26 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Technical data Altitude above sea level Ʋ...
  • Page 27 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Technical data Aluminium housing with protection rating IP66/IP68 (1 bar) ~ 105 mm ~ 150 mm (4.13") (5.91")
  • Page 28 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Technical data Stainless steel housing with protection rating IP66/IP68 (1 bar) ~ 93 mm (3.66") ø...
  • Page 29 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Technical data NivoGuide 8200, cable version with gravity weight SW 60 (2.36") G1½...
  • Page 30 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Technical data Cable ø 2 mm (0.079 in) Cable ø 4 mm (0.157 in), temperature version -196 … +450 °C (-321 … 842 °F) Max.
  • Page 31 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Technical data NivoGuide 8200, cable version with centering weight SW 60 (2.36") G1½...
  • Page 32 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Technical data Max. height of the vessel insulation NivoGuide 8200, rod version SW 60 (2.36")
  • Page 33: Mounting

    ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Mounting General instructions Devices with threaded fitting are screwed into the process Screwing in fitting with a suitable wrench via the hexagon.
  • Page 34 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Mounting detailed information on the process conditions in chapter "Technical data"...
  • Page 35 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Mounting Fig. 20: Vessel with conical bottom Plastic vessel/Glass vessel Type of vessel The guided microwave principle requires a metallic surface...
  • Page 36 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Mounting Fig. 21: Mounting in non-metallic vessel Flange 2 Metal sheet If possible, avoid nozzles.
  • Page 37 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Mounting Fig. 23: Nozzle must be installed flush Unfavourable mounting 2 Nozzle flush - optimum mounting Before beginning the welding work, remove the electronics...
  • Page 38 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Mounting The reference plane for the measuring range of the sensors is Measuring range the sealing surface of the thread or flange.
  • Page 39 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Mounting at the probe end to avoid contact with the tube wall. In the case of cable probes, the cable can be strained.
  • Page 40 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Mounting Standpipes or surge pipes are normally metal tubes with a Standpipes diameter of 30 …...
  • Page 41 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Mounting ø 150 - 200 mm ø...
  • Page 42 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Mounting • The 0 % point in standpipes should be above the gravity or centering weight.
  • Page 43 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Mounting Avoid undefined vessel connections, i.e. the connection must be either grounded reliably or isolated reliably.
  • Page 44 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Mounting In case of difficult installation conditions, the probe can also Lateral installation be mounted laterally.
  • Page 45: Connecting To Power Supply

    ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Connecting to power supply Preparing the connection Always keep in mind the following safety instructions: Safety instructions •...
  • Page 46 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Connecting to power supply in at the factory. The free openings for the cable glands are therefore covered with red dust protection caps as transport protection.
  • Page 47 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Connecting to power supply Proceed as follows: Connection procedure Unscrew the housing lid 2.
  • Page 48 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Connecting to power supply Wiring plan - single chamber housing The following illustration applies to the non-Ex, Ex ia and Ex d version.
  • Page 49 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Connecting to power supply Connection compart- ment 4...20mA Display...
  • Page 50 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Connecting to power supply Switch-on phase After connecting the instrument to voltage supply or after a voltage recurrence, the instrument carries out a self-check for approx.
  • Page 51: Functional Safety (Sil)

    ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Functional safety (SIL) Objective In case of dangerous failures, processing facilities and ma- chines can cause risks for persons, environment and prop- erty.
  • Page 52 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Functional safety (SIL) ed systems (SIS) according to IEC 61508 and IEC 61511. Take note of the specifications in the Safety Manual.
  • Page 53 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Functional safety (SIL) ment"). The device status is indicated by the symbol of an unlocked or locked padlock.
  • Page 54 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Functional safety (SIL) Generally the instrument is in safe operating state before the adjustment is released.
  • Page 55 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Functional safety (SIL) To interrupt the function test, you have to push the button "ESC".
  • Page 56 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Functional safety (SIL) For this purpose, you have to measure for all levels the cur- rent output and compare the values with the calculated current values.
  • Page 57: Set Up With The Display And Adjustment Module

    ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module Insert display and adjustment module The display and adjustment module can be inserted into the sensor and removed again at any time.
  • Page 58 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module Fig.
  • Page 59 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module Adjustment system Fig.
  • Page 60 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module Fig.
  • Page 61 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module In the second view, the selected measured value and a re- spective bargraph presentation are displayed.
  • Page 62 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module The submenu points are described below.
  • Page 63 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module In this menu item, you can select the application.
  • Page 64 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module this menu item you can enter if there is a superimposed gas phase in your application.
  • Page 65 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module to the sensor reference plane (seal surface of the process fitting).
  • Page 66 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module This menu item is only available if you have selected inter- Min. adjustment - In- face measurement under the menu item "Application".
  • Page 67 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module considered by the user especially when setting the switching point on the limit signal transmitter.
  • Page 68 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module In the menu item "Current output Min./Max.", you determine Current output - Min./ the reaction of the current output during operation.
  • Page 69 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module If a false signal suppression has already been saved in the sensor, the following menu window appears when selecting "False signal suppression":...
  • Page 70 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module In the next step, the instrument checks the data of the measurement and decides by means of the evaluation results if a functions test is required.
  • Page 71 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module If the described process of parameter adjustment was run through completely and correctly, the instrument will be locked and hence ready for operation.
  • Page 72 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module This menu item enables the setting of the requested national Menu language language.
  • Page 73 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module In delivery status, the lighting is switched on.
  • Page 74 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module In another window you can carry out a reset of the two peak values separately.
  • Page 75 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module In this menu item you can simulate measured values via the Simulation current output.
  • Page 76 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module Parameter settings for recording the echo curve and the set- tings of the echo curve itself can be carried out in the adjust- ment software PACTware.
  • Page 77 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module Delivery status: Restores the parameter settings at the time of shipment from the factory, incl.
  • Page 78 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module Menu item Default value Max.
  • Page 79 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module Menu item Default value Third HART variable (TV)
  • Page 80 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module Menu item Default value Time - Format...
  • Page 81 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module Tip: We recommend to save the instrument adjustments.
  • Page 82 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module In menu item "Scaling format"...
  • Page 83 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module The default setting is "Analogue current output"...
  • Page 84 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Set up with the display and adjustment module Save parameter adjustment data We recommended writing down the adjustment data, e.g.
  • Page 85: Diagnosis, Asset Management And Service

    ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Diagnosis, asset management and service Maintenance If the device is used properly, no special maintenance is re- Maintenance quired in normal operation.
  • Page 86 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Diagnosis, asset management and service Fig. 40: Pictographs of the status messages Failure - red 2 Out of specification - yellow 3 Function check - orange...
  • Page 87 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Diagnosis, asset management and service Code Cause Rectification DevSpec State...
  • Page 88 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Diagnosis, asset management and service Code Cause Rectification DevSpec State...
  • Page 89 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Diagnosis, asset management and service Maintenance Code Cause Rectification...
  • Page 90 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Diagnosis, asset management and service Error Cause Rectification 4 … 20 mA signal missing...
  • Page 91 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Diagnosis, asset management and service Measurement error with constant level Fault description Cause Rectification...
  • Page 92 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Diagnosis, asset management and service Fault description Cause Rectification Measured value jumps to...
  • Page 93 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Diagnosis, asset management and service In the factory Order the replacement electronics module from the agency serving you.
  • Page 94 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Diagnosis, asset management and service Caution: Make sure that the two components of the double washer remain together.
  • Page 95 ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Diagnosis, asset management and service Cable with centering weight: Fasten cable with the pins, torque 7 Nm (5.16 lbf ft) and fix the clamping part on the centering weight.
  • Page 96: Dismount

    ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Dismount Dismounting steps To remove the device, carry out the steps in chapters "Mounting"...
  • Page 97: Supplement

    ® ® Continuous level measurement Continuous level measurement NivoGuide NivoGuide NG 8200 - Rod and cable probe NG 8200 - Rod and cable probe Technical information / Instruction manual Technical information / Instruction manual Supplement Trademark All the brands as well as trade and company names used are property of their lawful proprietor/originator.
  • Page 98 INDEX Function test 54, 70 Accessories – Display and adjustment module 10 Gas phase 63 Adjustment Grounding 46 – Max. adjustment 64, 65 – Min. adjustment 65, 66 Adjustment system 59 HART address 82 Application 63, 64 Application area 6 Inflowing medium 37 Installation position 34 Backlight 72...
  • Page 99 Sensor characteristics 83 Serial number 6 SIL 51 Simulation 75 Special parameters 83 Type label 6 Type of medium 62 Units 62 Unlock adjustment 69 Verify parameter 56 Vessel insulation 42 page 99...
  • Page 100 ® Continuous level measurement NivoGuide NG 8200 - Rod and cable probe Technical information / Instruction manual page 100...
  • Page 101 ® Continuous level measurement NivoGuide NG 8200 - Rod and cable probe Technical information / Instruction manual page 101...
  • Page 102 ® Continuous level measurement NivoGuide NG 8200 - Rod and cable probe Technical information / Instruction manual page 102...
  • Page 103 ® Continuous level measurement NivoGuide NG 8200 - Rod and cable probe Technical information / Instruction manual page 103...
  • Page 104 Subject to change without prior notice Technical support Please contact your local sales partner (address at www.uwtgroup.com). Otherwise please contact us: UWT GmbH Phone + 49 (0) 831 57 123 0 Westendstraße 5 87488 Betzigau info@uwtgroup.com Germany www.uwtgroup.com...

Table of Contents