Yamaha CobraNet MY16-C Owner's Manual page 18

Interface card

Advertisement

Connecting to Other CobraNet Devices
DME64N
Audio signal and
control data
Audio signal and
control data
1
2
3
4
5
6
7
8
EXT.
NETWORK
CLOCK
PEAK
96kHz
MID
88.2kHz
MASTER
SIGNAL
IN
48kHz
1
2
3
4
5
6
7
8
44.1kHz
PEAK
SCENE NUMBER
SIGNAL
OUT
DME24N
n Not compatible with ACU16-C or NHB32-C control signals.
CobraNet Redundancy Network
n Redundancy Networks
Redundancy networks employ dual (primary and secondary) circuits. Communication usually
occurs over the primary circuit, but if a failure occurs on the primary circuit – cable failure,
accidental disconnection, switch failure, etc. – the secondary circuit will automatically take over.
Redundancy networks offer significantly higher reliability compared to single-circuit systems.
1
2
3
4
5
6
7
8
EXT.
NETWORK
CLOCK
PEAK
96kHz
MID
88.2kHz
MASTER
SIGNAL
IN
48kHz
1
2
3
4
5
6
7
8
44.1kHz
PEAK
SCENE NUMBER
SIGNAL
OUT
DME24N
DME64N
MY16-C
MY16-C
MY16-C
DME24N
Switching Hub A
MY16-C
DME64N
ACU16-C
Switching Hub
LINK
CONDUCT
LOCK
ERROR
NHB32-C
1
2
3
4
5
6
7
8
EXT.
NETWORK
CLOCK
PEAK
96kHz
MID
88.2kHz
MASTER
SIGNAL
IN
48kHz
1
2
3
4
5
6
7
8
44.1kHz
PEAK
SCENE NUMBER
SIGNAL
OUT
MY16-C
Switching Hub B
MY16-C
MY16-C Owner's Manual
Straight Cable
Audio signal only
Audio signal only
NETWORK HUB AND BRIDGE
88
Straight Cable
(Primary CobraNet)
Straight Cable
(Secondary CobraNet)
17

Advertisement

loading