WARNING
Wear Safety Goggles
Avoid Contact with Refrigerant
STATIC DISCHARGE: Climates in some parts of the world are conducive to creating static electric build up (ESD). Your scale has been
designed to eliminate the damaging effects of ESD. In some extreme cases, ESD will be apparent on your scale by a lack of response or an
inability to turn off the unit. In the rare case that this occurs, simply disconnect the battery, wait 1 minute and reconnect the battery. The
scale will "reboot" itself and operate normally once the unit is turned on.

KEY FUNCTIONS

ON/OFF:
Turns unit ON or OFF
UNIT/SHIFT: UNIT - readout in kg
SHIFT - Move from one digit to the next, to edit display / To set up tank capacity
To Increase Value
To Decrease Value
CHARGE/PAUSE: CHARGE - To start CHARGE/RECOVERY mode
PAUSE - To pause and resume in CHARGE/RECOVERY mode
TARE/ENTER:
TARE - zeros out display in BASIC CHARGING
ENTER - to start operation or input data
REPEAT:
REPEAT - to repeat the last action
CLEAR/ZERO:
ZERO - Long press to zero out the display if the weight is less than 2% of the scale capacity.
(See check list below)
CLEAR - Press to perform CLEAR function in charging or recovery.
CHECKLIST (Prior to 1st Use)
Your unit includes a 9V battery. Install battery. Place the platform on a flat surface and press on/off button to turn unit on.
The scale will display full text > software version > HELLO > maximum capacity and division 110.050 > weight.
* The weight must be more than minimum capacity of the scale.
Proceed to BASIC or PROGRAMMED CHARGING.
BASIC CHARGING
1. Remove platform from case.
2. Place platform on level surface.
3. Press ON/OFF button to turn unit on.
4. Place DOT tank in center of platform and connect to liquid port. (Place disposable tank upside down).
5. Make sure the charging lines and the system are free of air using deep vacuum pump. (Follow vacuum instructions)
6. Press TARE/ENTER button – display will read zero.
7. Open the valve to begin charging.
8. When the desired amount is reached, close the valve.
9. Press ON/OFF button to turn unit off.
PROGRAM CHARGING
1. Repeat steps (1 through 5) in BASIC CHARGING.
2. Press CHARGE/PAUSE button.
3. Set amount of refrigerant you want to charge using CLEAR,
4. Press ENTER to start.
5. Open the valve on the tank to begin charging. Just before charging is completed, a short alarm will sound, allowing
time to turn off supply.
6. When charging is completed, scale will sound an alarm again and display CH/END. Press any button to stop alarm. (If
the tank is empty and the charge is not complete, scale will stop automatically and display E-PTY, replace the tank and