press CHARGE/PAUSE to resume charging).
7. When the desired amount is reached, close the valve and press ON/OFF button to turn unit off.
• This unit is preprogrammed for minimum and maximum cylinder weight of 0 kg / 110 kg.
• To change cylinder weight setting, refer to INSTRUCTIONS FOR SETTING TANK CAPACITIES.
REPEAT CHARGING
1. Press REPEAT to start charging the previously stored amount.
2. Open the valve.
3. When desired amount is reached, close the valve and press ON/OFF to turn unit off. (If scale was turned off, follow
steps (1 through 5) of BASIC CHARGING, then follow the REPEAT CHARGING steps).
RECOVERY/RECYCLE
1. Repeat steps (1 through 7) in BASIC CHARGING.
2. Begin recycling.
3. The display indicates the amount of collected refrigerant when recycling is completed.
INSTRUCTIONS FOR SETTING TANK CAPACITY
1. Turn on the unit.
2. Select readout using UNIT/SHIFT.
3. Press UNIT/SHIFT again and hold down until the last digit in display "blinks".
4. Use CLEAR,
,
5. Press ENTER to set the empty tank weight. The display will read "GOOD" to confirm.
6. Use CLEAR,
,
7. Press ENTER to set the full tank weight. The display will read "GOOD - OUT" to confirm.
8. Press ON/OFF button to turn unit off.

SPECIFICATIONS

• Accuracy class: III
• Maximum capacity: 110 kg
• Minimum capacity: 400 g
• Resolution: 20 g to 55 kg, 50g to 110kg
• Temperature range: 0˚ to 40˚C
• Power supply voltage: 9 V battery
• Optional power supply: 9V DC plug in power supply
• Automatic shut off: 3 hours
REPLACING THE BATTERY
Replace 9V battery when a low-battery symbol prompts on LCD. DO NOT OPERATE with a low battery.
USING THE ELECTRONIC CHARGING SCALE AND THE MASTERCOOL CONNECT APP
1. Download the Mastercool Connect app to a hand-held smart device from the Apple App Store or Google Play Store.
2. Press the power key on the digital scale keypad to turn on the device.
3. Launch the Mastercool Connect app on the mobile device.
and SHIFT to input the empty tank weight.
and SHIFT to input full tank weight.
3

Advertisement

Table of Contents
loading

Table of Contents