Key Functions - MasterCool ACCU-CHARGE II Operating Instructions Manual

Electronic refrigerant scale with bluetooth wireless technology
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
WARNING
Wear Safety Goggles
Avoid Contact with Refrigerant
STATIC DISCHARGE: Climates in some parts of the world are conducive to creating static electric build up (ESD). Your
scale has been designed to eliminate the damaging effects of ESD. In some extreme cases, ESD will be apparent on your
scale by a lack of response or an inability to turn off the unit. In the rare case that this occurs, simply disconnect the
battery, wait 1 minute and reconnect the battery. The scale will "reboot" itself and operate normally once the unit is
turned on.

KEY FUNCTIONS

ON/OFF:
Turns unit ON or OFF
UNIT/SHIFT: UNIT - Select readout in lb, oz or kg
SHIFT - Move from one digit to the next, to edit display / To set up tank capacity
To Increase Value
To Decrease Value
CHARGE/PAUSE: CHARGE - To start CHARGE/RECOVERY mode
PAUSE - To pause and resume in CHARGE/RECOVERY mode
TARE/ENTER:
TARE - zeros out display in BASIC CHARGING
ENTER - to start operation or input data
REPEAT:
REPEAT - to repeat the last action
CLEAR:
Use to clear the display during PROGRAM CHARGING ONLY! (DO NOT use CLEAR for any other function!)
CHECKLIST (Prior to 1st Use)
Your unit includes a 9V battery. Install battery. Place the platform on a flat surface and press ON/OFF button to turn unit
on. The scale will begin counting down from 999999 to 000000! (DO NOT PRESS CLEAR while the unit is counting down).
Proceed to BASIC or PROGRAM CHARGING.
*If the digital readout displays a small weight (±.5 Ounce or ±20 Grams ) press and hold the TARE/ENTER button for
approximately 30 seconds until you hear a DOUBLE BEEP. The scale will automatically zero out. Proceed to BASIC or
PROGRAM CHARGING.
BASIC CHARGING
1. Remove platform from case.
2. Place platform on level surface.
3. Place DOT tank in center of platform and connect to liquid port. (Place disposable tank upside down).
4. Make sure the charging lines and the system are free of air using deep vacuum pump. (Follow vacuum instructions)
5. Press ON/OFF button to turn unit on.
6. Press TARE/ENTER button – display will read zero. (If the scale has not been used for a while press and hold TARE/
ENTER button to reset the scale).
7. Open the valve to begin charging.
8. When the desired amount is reached, close the valve.
9. Press ON/OFF button to turn unit off.
PROGRAM CHARGING
1. Repeat steps (1 through 5) in BASIC CHARGING.
2. Press CHARGE/PAUSE button.
3. Set amount of refrigerant you want to charge using CLEAR,
4. Press ENTER to start.
5. Open the valve on the tank to begin charging. Just before charging is completed, a short alarm will sound, allowing