TECHNICAL SAFETY INSTRUCTIONS

• EXCLUSIVELY DESIGNED FOR AIR BEDS
• DUAL FUNCTION: INFLATION & DEFLATION
• Max load: 350kg/772lbs.
Note: Do not exceed the maximum load recommended, or the airbed will be damaged
and even explode.
• Rating: 220-240V~, 50/60Hz, 139W.
• Content:1 air mattress, 1 storage bag, repair bag, manual

BUTTON FUNCTION DESCRIPTIONS

Green light: Inflation completed, reach the desired pressure;
Green light flashing: Alarm - Can not reach the desired pressure within 5 min.
Blue light: Inflating or Deflating;
Blue light flashing: Manual Deflating.
Auto-Deflation: Press deflation button for 3 seconds.
Manual-Deflation: If air bed is not deflated completely, press the deflation
button more than 4 seconds and holding it will cause the pump to go into a
manual-deflation state (with the blue LED flash), which has a 30-second
Auto-off feature.
USB port.
Specification: DC 5V 1A
The USB port can be powered when the pump plugs into the socket.
NOTE: When all 3 power buttons are flashing this indicates one of two things: 1) The power
is on, or 2) The power has been off and is now reconnected to a power source. This pump
has an auto-re-inflation feature. Please keep the pump plugged in and make sure the green
light is on to maintain the air pressure level that you choose.
NOTE: Pressing the deflation button anytime will stop the pump when it is in use.

TROUBLESHOOTING

PROBLEM
The green
LED flashes
CAUSE
The pump can not
reach the desired
pressure after
inflating over 5 min.
1. Check if there is any air is leaking and ensure the air
valve is closed. Unplug and re-start the air pump.
2. If the problem continues, please manually deflate the
product following the below steps:
• Press the deflation button and hold for more than
3 seconds and hold.
• Or press the deflation button once to open the air
valve in the pump and then deflate by pressing the
air out of the product.