Electrical Wiring - Maretron SH-003 Installation Instructions Manual

Smoke / heat detector - high temp kit

Advertisement

3 Electrical Wiring

Note:
These wiring instructions show connections to channel 'SW1' of the SIM100; however, connections
could be made to other channels of the SIM100 using the same method. The SIM100 can support up
to 6 detector areas.
4 Detector Behavior
When a detector is triggered or in Test Mode the detector's sounder will sound, the detector base
relays will change state, and the integrated Red LED will illuminate solid.
To reset an alarm state or exit Test Mode on a detector, the detector's power will need to be cycled.
S/H Detector Unit
Power-Up
Standby (Detector OK)
Alarm State
Revision 1.3
LED Reporting Modes
No LED
Red LED will periodically blink
Red LED will illuminate solid
EOL Relay
Standby
Loss of Power/Alarm State
Red LED ON
Red LED OFF
Page
5