Tub-Shower Mixing Valves
Installation Brief
Model number
S-46-2-BODY .. Temptrol Tub-Shower
mixing valve
S-46-1-BODY .. Temptrol Shower
mixing valve
S-46-2X-BODY Temptrol Tub-Shower
mixing valve with stops
S-46-1X-BODY Temptrol Shower
mixing valve with stops
Rough-in Installation
Installing control valve, piping & fittings
Reference rough-in dimension illustration
on page 2 as required.
1)
Determine wall thickness
■ Determine type of wall and wall
thickness where valve will be mounted.
■ Consider whether to use mounting plate
by reviewing figure 2 below.
■ Skip ahead to
if mounting
Step 3
plate will not be used.
2)
Attach mounting plate to valve
Seat mounting plate against valve
assembly as illustrated in figure 1.
Walls for using T-177 mounting plate
Fiberglass or acrylic walls (required)
Plaster or other type walls (optional)
1/16" (2 mm) min 1/2" (13 mm) max
Protective shield
When mounting plate is used,
then shield is optional for
protecting end of valve during
installation.
"snap on-off"
p/n T-176
wall cutout hole size
3-1/2" (89 mm) min
Temptrol
Tools & Materials
Plumbers
Putty
3)
Attach protective shield
■ Reference figure 2 to determine
whether shield is required.
■ Attach plastic protective shield by
snap fitting over end of valve spindle.
nished
wall
p/n T-177
4" (102 mm) max
Figure 2 Mounting valve
®
S-46-2(X)-BODY, S-46-1(X)-BODY
1
2
3
4
Figure 1 Mounting
plate
Dry wall, plaster or other type wall
1/2" (13 mm) or greater
Ensure valve's
(60 mm ± 13 mm)
mounting plate
pipe centerline
is ush against
to nished wall
inner wall
Finished wall must be
ush with back side of
protective shield surface
Protective shield
"snap on-off"
(required when
mounting plate
is not used)
wall cutout hole size
3-1/2" (89 mm) min
4" (102 mm) max
Need Help?
Contact Symmons customer service
at (800) 796-6667, (781) 848-2250,
gethelp@symmons.com
Mon - Fri 7:30 am - 7:00 pm EST
Please check Symmons website
for technical help, the latest product
information and warranty policy.
www.symmons.com/service
4)
Install piping, fittings and
control valve
Piping and fittings not supplied
■ Control Valve
Install valve through cutout hole in
wall as specified in figure 2 below and
dimension illustration on page 2.
■ Showerhead (S on valve)
Pipe from outlet port on valve marked
to showerhead mounting arm location.
■ Hot & Cold Supply (H & C)
Pipe hot water supply to valve input
marked
and cold water supply to
H
valve input marked
■ Tub Spout (T on valve)
Pipe from outlet port on valve marked
T
to tub spout. (
nished wall
2-3/8" ± 1/2"
S
.
C
only)
S-46-2-BODY
Need help?
Do you have a question about the Temptrol S-46-2-BODY Series and is the answer not in the manual?
Questions and answers