Download Print this page

Pioneer PD-6010 Service Manual page 50

Advertisement

PD-6010
Oscilloscope
Step
position
No.
Adjustment
positions
Check items/
Adjustment
specifications
Adjustment procedure
61
TP 1
Pin 6
(FO. IN)
TP 1
Pin 1
(FO, OT)
VR3
(FO. GA)
LED (green) on
Note:
If adjusting
the output
voltage by oscilloscope,
discon-
nect the cable from the F.T.G adjuster circuit board, and
Measure and adjust with the oscilloscope probe in direct
contact
with pin 3 of the N1 connector (plug). (Because
of the hum
generated,
do not measure at the tip of the
cable.)
C.D PLAYER
a'
(¥—7—_
7]
Pin6
ORANGE WIRE
(FO. IN)
Pin 1
(FO. OT)
F.T.G.
Adjustor
BROWN WIRE
BLACK WIRE
Pin 5
(GND)
TP 1
(R-878)
Oscilloscope
Position
Vv
H
Test
points
Adjustment
Positions
Check items/
Adjustment
specifications
Adjustment procedure
62
TP 1
Pin 7
(TR. IN)
TP 1
Pin 2
(TR. OT)
VR4
(TR. GA)
LED (green) on
@
Press the STOP
Key
(
(1) to switch all servos off.
Note:
If adjusting the output volage by oscilloscope, disconnect
the
cable
from
the
F.T.G
adjuster circuit board,
and
measure and adjust with the oscilloscope Probe in
direct
contact with pin 4 of the N1 connector (plug). (Because
of the hum
generated,
do no measure
at the tip of the
cable.}
C.D PLAYER
TP 1
Pin 7
YELLOW WIRE
F.T.G.
(TR. IN) al
Adjustor
Pin 2
| RED WIRE
Oo
(TR. OT) | |
BLACK WIRE
Pin 5
O-
(GND)
|

Advertisement

loading

This manual is also suitable for:

Pd-6010bk