Error and End
Optional
CAUSES OF MR, ER,
AND LOR REPORTS
Communication Buffers
•
This report indicates that ER and END conditions as previously
indicated have occurred since the previous SEL to the particular buffer.
•
These reports indicate a condition unique to a particular buffer which
is to be reported to the program in a coordination message. No action
other than the generation of the coordination message is performed by the
CCM.
RPT 3
RPT 2
RPT 1
Report or Condition
0
0
0
Quiescent
0
0
1
End
0
1
0
Error
0
1
1
End and Error
1
0
0
Malfunction
1
0
1
Ring
1
1
0
Optional 1 (LDR, BDR*)
1
1
1
Optional 2
*Break Disconnect Report - 70/720-22.
•
Malfunction, Error, and Line Disconnect Reports are reported to the
CCM by the buffers as a result of certain detected conditions normally
related to the communication line, the data set, or the automatic calling
unit. The following is a list of the reports generated to the various buffers
depending upon the abnormal conditions present:
Buffer
Report
Command
Condition Reported
70/710
MR
TC
Bit-echo check failure.
70/715
MR
TC
Loss of
oop
from VRU.
ER
TC
Presence of data in 70/715
at the end of a WT pulse.
LDR
TC
Absence or loss of DSR.
LDR
RC
Loss of DSR.
70/720-11,21
MR
TC
Loss of DSR.
RC
Loss of DSR.
ER
TC
Loss of RD or SRD.
RC
Loss of DCD.
70/720-22
MR
TC
Loss of DSR.
MR
RC
Loss of DSR.
ER
TC
Loss of CTS.
4-4