Ccd Black Defect Compensation - Sony Cyber-shot DSC-P2 Service Manual

Level 2
Hide thumbs Also See for Cyber-shot DSC-P2:
Table of Contents

Advertisement

19. CCD Black Defect Compensation

Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of page: 6,
address: 55
Measuring Instrument
Adjusting remote commander
Note 1: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 2: Check that there are no dust, no dirt and reflection of the
clear chart.
Note 3: Any subject other than the clear chart should be in the
screen.
Adjusting method:
Order Page Address Data
1
2
E
65
3
E
65
4C
4
6
2C
01
5
6
90
00
6
6
91
03
7
6
92
00
8
6
93
00
9
6
01
79
10
6
30
08
11
6
07
12
13
6
01
8D
14
6
02
15
6
55
16
6
01
00
17
E
65
5A
18
6
01
89
19
6
02
20
6
55
Note 4: If the data is "00" at the check in this adjustment method
order #15, skip the orders from #16 to #20 , and go for-
ward to "Processing after Completing Adjustment.
RadarW
RadarW
RadarW
RadarW
RadarW
Procedure
Perform "Data setting during
camera system adjustment".
(Refer to page 5-14)
Note down the data.
Press PAUSE button.
Press PAUSE button.
Check the data changes to
"01".
Wait for 4 seconds.
Press PAUSE button.
Check the data changes to
"01".
Check the data.
00 to 14 : Normal
15 to FF : Defective
(Note 4)
Press PAUSE button.
Press PAUSE button.
Press PAUSE button.
Check the data changes to
"01".
Check the data.
00: Normal
01 to FF: Defective
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
2C
3
6
30
4
6
91
5
E
65
6
5-29
DSC-P2
Procedure
00
Press PAUSE button.
00
00
00
Set data noted down at step
2, and press PAUSE button.
Release the data setting
performed at step 1.
(Refer to page 5-14)

Advertisement