Advertisement

Order Page Address Data
41
6
02
42
6
01
00
43
6
90
00
44
6
91
00
45
6
01
79
46
6
07
47
6
01
B9
48
49
6
02
50
6
01
00
51
6
01
E7
52
53
6
02
EA
54
F
EC
EE
55
0
03
2C
56
1
57
0
03
2D
58
1
Note 6: The adjustment data will be automatically input to page:
F, address: B6 to B7 and DB to EF.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
00
2
6
90
00
3
6
91
00
4
6
92
00
5
6
93
00
6
6
2C
00
7
6
6C
00
8
0
03
00
9
4
1E
10
Procedure
Check the data changes to
"01".
Press PAUSE button.
Press PAUSE button.
Check the data changes to
"01".
Press PAUSE button. (Note 6)
Check the flashing.
Check the data changes to
"01".
Press PAUSE button.
Press PAUSE button.
Check the flashing.
Check the data changes to
"01".
Check that the displayed data
satisfies the Y level specified
value.
Check that the R-Y level data
(Note 4) satisfies the specified
value.
Check that the B-Y level data
(Note 4) satisfies the specified
value.
Procedure
Press PAUSE button.
Set data noted down at step
3, and press PAUSE button.
Release the data setting
performed at step 1.
(Refer to page 5-14)
5-31
DSC-P2

Advertisement

Table of Contents
loading