Electrical Requirements; Gas Connection Requirements; Test Performance Specifications - LACO Technologies LHCT03D Operation And Maintenance Manual

Helium concentration tester
Table of Contents

Advertisement

4 EQUIPMENT DESCRIPTION
12

Electrical Requirements

Depending on the Helium Concentration Tester configuration the electrical
requirements will fall into one of the two groups listed below.
Electrical Service Requirement
120 V~, 50/60 Hz, 1~, 5 Amp Max
208-240 V~, 50/60 Hz, 1~, 5 Amp Max
Feature
Overall IP rating
Enclosure Nema rating

Gas Connection Requirements

Helium that is sampled in the gas sniffer must be only a maximum of 5 PSIG.

Test Performance Specifications

Feature
Supported Leak
Detectors
Detectable Gases
Startup Time
Accuracy
Response Time
Measurement Range
Flow
LHCT03D & LHCT03D-R Operations and Maintenance Manual
Main Power Cable Requirements
IEC C13, 16 AWG, 3 cond.
IEC C13, 16 AWG, 3 cond.
Specifications
1
1
Performance Specifications
LACO TITANTEST, Inficon LDS-3000 or LDS-2010, Alcatel
180T or 182T
Helium (He)
Depends on Leak Detector startup time
5% of full scale
Less than 5 seconds (typical)
1% to 100% Helium
120 sccm
LACO Technologies

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lhct03d-r

Table of Contents