Operating Controls
VU Meter Selector: switches ASA - standard VU meter to read:
L or R Input Level
L or R Compressor Output
L or R Filter Out
L or R Line Amplifier Output
+15 V Power Supply Voltages
(L INPUT BUFFER)
(L COMPR OUT)
(L FILTER)
(L SYSTEM OUT)
Setup
Controls
( front- panel,
behind
lockable
swing- down
door --
see
Fig.
4-5)
Compressor:
Left and Right Input Attenuators
"Master" Band Release Time
Release Shape Switch
Gate Threshold
Bass Coupling
Clipping
High- Frequency Limiter Threshold
General:
Left and Right Output Attenuators
PROOF/OPERATE Switches ( to defeat gain reduction, HF limiting, clipping, and
gating)
Loudness Controller ON/OFF Switch
Power ON/OFF Switch
115V/230V Selector Switch
Power Requirement
115/230VAC, + 15%,
50-60Hz,
approx.
31VA.
IEC
mains
connector
with
detachable 3- wire " U- Ground" power cord supplied. Leakage to chassis less than
0.5mA. AC is RF - suppressed.
Dimensions
19"(48.3cm)W x 7"(17.8cm)H x 12.5"(31.2cm)D -- 4 rack units
Environmental
Operating Temperature Range: 0-50 degrees C ( 32-122 degrees F).
Humidity: 0-95% R.H., non- condensing