Download Print this page
Bioland G-430P Owner's Booklet

Bioland G-430P Owner's Booklet

Pet blood glucose monitor

Advertisement

Quick Links

Advertisement

loading

Summary of Contents for Bioland G-430P

  • Page 2 Table of Contents Information Important Information: Read This First! ----------------------------4 Specifications -------------------------------------------------------------6 Pet Blood Glucose Monitoring System -----------------------------8 Replacing the Batteries -------------------------------------------------9 Caring for the System --------------------------------------------------10 Pet Blood Glucose Test Strip -----------------------------------------11 Pet Blood Glucose Meter ----------------------------------------------13 Pet Blood Glucose Meter Display ------------------------------------14 Using the Lancing Device ----------------------------------------------16 Preparing the Lancing Device -----------------------------------------17 Preparing the Meter and Test Strip ----------------------------------18...
  • Page 4 20-60 20-60...
  • Page 6 Absorbent Hole Apply a drop of blood here. The blood will be drawn in automatically. Confirmation window This is where you confirm if enough blood has been applied to the absorbent hole of the strip. Test Strip handle Hold this part to insert the strip into the slot. Contact bars Insert this end of the test strip into the meter.
  • Page 7: Lcd Display

    STRIP PORT Where you insert the test strip. The meter will turn on automatically LCD DISPLAY It guides you through the test using symbols and simple messages STRIP EJECTOR Slide forward to eject the test strip after test 4 “M” BUTTON It is used to turn on the meter, enter the memory mode...
  • Page 8 BLOOD DROP SYMBOL TEST RESULT AREA Flashes when it is ready Displays glucose results to apply the blood sample MEASUREMENT UNIT LOW BATTERY SYMBOL Appears with the test Appears when the battery result in mg/dL power is low CTL SYMBOL KETONE REMINDER Appears when doing a control test and indicates...
  • Page 9 On the lancets and the lancing device. If your lancing device differs from the one shown here, please refer to the manufacturer’s manual to ensure proper usage.
  • Page 13 Battery power is low. Error massage indicates that you may remove the strip after applying blood to the absorbent hole. Environmental tem- perature is lower than 10 (50 ) or higher than 40 (104 ) Use a used test strip.
  • Page 14 The meter self-inspection is failure.
  • Page 15 20-60%.