Bioland G-427B User Manual
Hide thumbs Also See for G-427B:

Advertisement

®
Bioland

Blood Glucose Meter

Model:G-427B
G-427B
Blood Glucose Meter
Manufacturer:
BIOLAND TECHNOLOGY LTD.
th
A6b7 (Block G), Shangrong Ind. Zone, Baolong 5
Rd, Longgang
Distinct, Shenzhen Guangdong, CHINA 518116
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for Bioland G-427B

  • Page 1: Blood Glucose Meter

    ® Bioland Blood Glucose Meter Model:G-427B G-427B Blood Glucose Meter Manufacturer: BIOLAND TECHNOLOGY LTD. A6b7 (Block G), Shangrong Ind. Zone, Baolong 5 Rd, Longgang Distinct, Shenzhen Guangdong, CHINA 518116 User Manual...
  • Page 2 Dear G-427B Blood Glucose Monitoring System Owner: Read this before using Thank you for choosing this system! This manual contains important information you must know about the system. DANGER - Misuse of this electrical device can cause electrocution, burns, fire Please read it thoroughly and carefully.
  • Page 3: Beforeyour Begin

    BeforeYour Begin Installing the battery 1. Open the battery cover on the back of meter. 2. If replacing the batteries, please remove the used batteries. 3. Insert 2 new (AAA) batteries with correct +/- direction. 4. Close the battery cover. Environment Protection –...
  • Page 4: Intended Use

    G-427B Blood Glucose Monitoring System intended to be used by a single only during steady – state times (when glucose is not changing rapidly). person and should not be shared. The G-427B blood glucose test strips are for use with the Blood Glucose  ...
  • Page 5: Contents Of The Kits

    Blood Glucose Meter Test principle The test is based on the measurement of electrical current generated by the 1. Strip port reaction of glucose with the reagent of the strip. The meter measures the current Where you insert the test strip into and displays the corresponding blood glucose level.
  • Page 6: Meter Screen Display Message

    Meter Screen Display Message Test Strip Blood drop Each strip can be used only once. The test strip consists of the following parts: symbol 1-Absorbent hole Flashes when it is Apply a drop of blood here. The blood will be drawn in ready to apply the automatically.
  • Page 7: Setting The Meter And Deleting The Memory

    2. Set the unit (mg/dL or mmol/L) Setting the meter and deleting the memory 2.1 mg/dL → mmol/L With the “mg/dL” displaying, press “M” button until 1. Setting the date and time the “mmol/L” appears, press “S” button twice again 1.1 Setting the Year until the meter turn off.
  • Page 8: The Two Measuring Modes

    The two measuring modes Testing with blood sample The meter provides you with two modes for measuring, General and CTL. The CTL mode should be used when a control solution is being tested. See the table CAUTION: below. To reduce the chances of infection: ...
  • Page 9: Overview Of The Lancing Device

    Overview of the Lancing Device Setting Up the Lancing Device A. Device Cap Handle Needle Cap D. Needle Holder Device Body 1. Screw the device cap off. 2. Put the needle into the 3. Screw the needle cap and needle holder until the put it in the recycling Connecting Collar bottom.
  • Page 10: Preparing The Puncture Site

    The screen will display a flashing blood drop and Bluetooth symbol, time and date. Fingertip testing NOTE: Be sure to use G-427B blood glucose test strips, other Hold the lancing device firmly against the side of test strips may not produce an accurate result.
  • Page 11: Reference Value

    A countdown of 5 seconds starts. Reference value Note: make sure the confirmation window of the Test Strip is completely filled Time of day Normal plasma glucose rang for people without with your blood sample. diabetes Before breakfast (fasting) <100 mg/dL Two hours after meals <140 mg/dL Step 7...
  • Page 12: Control Solution Test

    Hold the meter to move the absorbent hole of test strip so it touches the drop. CONTROL SOLUTION TEST Once the confirmation window fills completely, the meter will begin counting Material needed: down.  Glucose Meter To avoid contaminating the control solution, do not directly apply control ...
  • Page 13: Viewing Results On The Meter

    Reading the Average of Blood Glucose Results Viewing Results on the Meter When the meter is off, press and hold the “M” button until the Your meter stores the 500 most recent blood glucose test results with dates and DAY AVG flashing, release button then 7-day average results times.
  • Page 14: Cleaning And Disinfection

    (for example, display will be clear to see after cleaning); and disinfection can avoid the infection to you or to the Model: G-427B other people, and the cross-infection. We strongly warn that the device should be Machine size: 90mm (L)×54mm (W)×13mm(H)
  • Page 15: Limitations Of Use

    14. Icodextrin ≤13 mg/dL Limitations of use: 15. L-dopa ≤ 10 mg/dL The blood Monitoring System is not intended for use on neonates.  16. Maltose ≤ 900 mg/dL  The blood Monitoring System is not intended for use on artery blood, 17.
  • Page 16: Display Message

    range DISPLAY MESSAGE Problems MESSAGE WHAT IT MEANS ACTION Problems Causes Solutions The message indicates very 11. Battery may be installed Blood glucose level is lower low blood sugar. You should improperly. than 20mg/dl consult with your healthcare 1.Install Battery 22.
  • Page 17 The chart below shows the results of a study where 350 typical users used the G-427B meter to test their blood glucose level. In this study, the G-427B meter gave result within 15% of their true blood glucose level 340 out of 350 times.
  • Page 18 Electrical and safety standards FCC Requirement This meter complies with CISPR 11: Class B (Radiated Only). Emissions of the changes or modifications not expressly approved by the party responsible for energy used are low and not likely to cause interference in nearby electronic compliance could void the user’s authority to operate the equipment.