Hp-Ib Address Selection - HP 3314A Manual

Function generator
Hide thumbs Also See for 3314A:
Table of Contents

Advertisement

Installation
REMOVE
Model 3314A
Figure 2-3. Z-AXIS Polarity Selection
2-5. Z-AXIS POLARITY SELECTION
The polarity of the Z-Axis output can be inverted by set-
ting $501 on the A2 PC board. This switch is set at the
factory to output positive (> +5V) blanking pulses,
negative (< —5V) intensifying pulses and OV baseline.
To gain access to this switch:
1, Disconnect the 3314A from its power source.
2. Remove the top handle and then the top cover.
3. Remove the three screws that secure the A3 PC
Assembly shield to the main deck. See Figure 2-3.
4. Raise the A3 PC Assembly on its hinges to expose
the A2 PC Assembly.
5. S501 is located at the left edge of the A2 PC
Assembly.
6. Set S501
as required.
"BLK-"
is for negative
blanking
pulses.
"ВІК--"
is for positive
blanking
pulses.
7. Re-assemble the 3314A.
2-6. HP-IB ADDRESS SELECTION
The HP-IB address is set from the front panel and
stored in non-volatile memory.
2-2
To view the address:
1. Press the blue shift key and then the LCL key. The
current address will be displayed for about 1/2 second.
To change the address:
1. Press the RECALL
key and then the LCL key.
The current address will be displayed indefinitely.
2. Set the 3314A's address from 0 to 30 inclusive with
the Modify knob. Address 31 is not allowed. Increment-
ing the past 30 sets the address to Listen Only. When the
3314A is set to Listen Only, the displayed address will be
ТО"
;
3. Press the STORE key and then the LCL key to ex-
ecute the entry.
The HP-IB address is set at the factory to 7. 7 is also the
default address if the non-volatile memory is lost.
If you are using a controller in the ''command'' mode
or are using an older type that requires the Talk and
Listen addresses, use Table 2-1 to determine the proper
addresses.
2-7. POWER ON AND OPERATOR'S CHECKS
Connect the 3314A to its power source using the power
cord provided. If the power cord included with your
3314A is not compatible with the outlet, contact your
nearest -hp- office for a replacement.