Immergas VICTRIX HYBRID PLUS Manual page 40

Hide thumbs Also See for VICTRIX HYBRID PLUS:
Table of Contents

Advertisement

Horizontal intake/exhaust assembly kits Ø 80/125 (Fig. 24)
To install the kit Ø 80/125 one must use the flanged adapter kit (pos. 2, Fig. 24).
1. Install the flanged adaptor (2) on the central hole of the appliance, positioning gasket (1) with the circular projections downwards in
contact with the appliance flange, and tighten using the screws contained in the kit.
2. Engage the bend (3) with the male side (smooth) to the end stop on the adapter (2).
3. Fit the Ø 80/125 (4) concentric terminal pipe with the male side (smooth) to the female side of the bend (3) (with lip seals) up to the end
stop, making sure that the internal (5) and external wall sealing plates (6) have been fitted; this will ensure sealing and joining of the
elements making up the kit.
3
4
2
1
Extensions for horizontal kit Ø 80/125 (L = maximum length) (Fig. 25).
The kit with this configuration can be extended up to a max. length of 32 m, including the terminal with grid and excluding the concen-
tric bend leaving the appliance.
If additional components are assembled, the length equivalent to the maximum allowed must be subtracted.
In this case the special extensions must be requested.
40
5
6
The adapter kit includes (Fig. 24):
C
13
N°1 Gasket (1)
N°1 Adapter Ø 80/125 (2)
The Ø 80/125 kit includes (Fig. 24):
N°1 Concentric bend Ø 80/125 at 87° (3)
N°1 Int./exhaust concentric terminal Ø 80/125 (4)
N°1 Internal wall sealing plate (5)
N°1 External wall sealing plate (6)
The remaining kit components must not be used
24
L
C
13
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

3.030699