Filling the condensate drain trap
When the appliance is switched on for the first time, combustion products come out of the con-
densate drain. After a few minutes of operation, check that combustion flue gases are no longer
coming out of the condensate drain; this means that the drain trap has filled to a correct con-
densate height that the flue gases cannot pass through.
Special provisions for appliances installed in B
Type B open chamber indoor units must not be installed in places where commercial, artisan
or industrial activities take place, which use products that may develop volatile vapours or
substances (e.g. acid vapours, glues, paints, solvents, combustibles, etc.), as well as dusts (e.g.
dust deriving from the working of wood, coal fines, cement, etc.), which may be harmful for
the components of the appliance and jeopardise operation.
In configuration B
installed in bedrooms, bathrooms, toilets or studios; they must neither be installed in rooms
containing solid fuel heat generators nor in rooms communicating with said rooms.
For appliances for domestic use (up to 35 kW) in B
rooms must be permanently ventilated, in compliance with the local regulations in force (at
least 6 cm
for each kW of heat input installed, except in the case of the presence of electrome-
2
chanical extractor fans or other devices that can depressurise the installation room).
Install the appliances in B
Failure to comply with the above implies personal responsibility and invalidates the warranty.
1.3
INSTALLATION WARNINGS
Victrix Hybrid Plus must be installed in strict compliance with the hydraulic and electrical
requirements set out in Parag. 1.11 and 1.12.
Only the following storage tank units can be installed:
- Inoxstor 200 - 300;
- Omnistor 300 - 500;
- Basic Magis Pro.
In order to connect the Victrix Hybrid Plus to the Inoxstor storage tank unit, connect the two coils in series, therefore it is NOT
possible to pair a thermal solar system.
For information related to the optional storage tank unit (size, connections, installation, etc...) refer to the relative instructions manuals.
or B
configuration.
23
53
and B
, unless local regulations are in force, the appliances must not be
23
53
and B
configuration in non-residential premises and which are permanently ventilated.
23
53
and B
configuration, the installation
23
53
11