Immergas VICTRIX HYBRID PLUS Manual page 101

Hide thumbs Also See for VICTRIX HYBRID PLUS:
Table of Contents

Advertisement

Id
Parameter
Parameter
Hydraulic
A0
model
Maximum
A1
pump speed
Minimum
A2
pump speed
Circulating
A3
pump mode
Storage tank
A4
flow offset
Storage tank
A5
DHW hysteresis
D.H.W.
A6
thermostat
Id
Parameter
Parameter
DHW mini-
S0
mum no. of fan
revs
DHW maxi-
S1
mum no. of fan
revs
Ignition phase
S2
no. of fan revs
Description
Defines the type of hydraulics in the indoor unit (0 =
instantaneous; 1 = cylinder)
Set this parameter from the control panel. see Par. 3.6
Set this parameter from the control panel. see Par. 3.6
Set this parameter from the control panel. see Par. 3.6
Establishes the temperature to be added to the DHW
set-point to calculate the flow set to heat the storage tank
(only useful with a coupled storage tank and parameter
A0=1).
Set this parameter from the control panel. see Par. 3.6
Not available for this model
Description
Defines the operating speed of the fan at minimum DHW
output (when paired with a storage tank unit)
Defines the operating speed of the fan at maximum DHW
output (when paired with a storage tank unit)
Defines the operating speed of the fan during the ignition
phase
Range
Default
0 ÷ 1
0
5 ÷ 50 °C
25
0 ÷ 15 °C
3
Range
Default
27 (G20)
20 - 60
(x 50 = RPM)
26 (G31)
121 (G20)
S0 - 140
(x 50 = RPM)
115 (G31)
44 (G20)
40 - 80
(x 50 = RPM)
44 (G31)
Customised
value
Customised
value
101