11. M-NET CONTROL
11-4-3-3. MA remote controller, Multi-refrigerant-system, System Controller at TB7/TB3 side, Booster for long M-NET wiring
PUHY
OC
OS1
TB7
TB7
51
52
CN40
CN41
CN40
CN41
DipSW5-1
DipSW5-1
ON
ON
TB3
TB3
PSU
Power supply unit (PSU)
(PAC-SC51KUA)
*2 *4
000 or 201
SC*3
203
SC
*1 For Wireless R/C and Signal receiver unit (SRU), channel 1, 2 and 3 are selectable and should be set to same channel.
*2 System controller should connect to TB7 at Outdoor and use power supply unit together in Multi-Refrigerant-System.
For AG-150A-A, 24VDC should be used with the PAC-SC51KUA.
For AE-200A, AE-50A, and EW-50A the power supply unit PAC-SC51KUA is unused.
*3 When multiple system controllers are connected in the system, set the controller with more functions than others as a "main"
controller and others as "sub".
AE-200A, AE-50A, EW-50A, and BAC-HD150 are for exclusive use as a "main" system controller and cannot be used as a "sub" system
controller. Make the setting to only one of the system controllers for "prohibition of operation from local remote controller".
*4 The power supply unit is not necessary for AE-200A, AE-50A, EW-50A, and BAC-HD150.
NOTE:
1. Outdoor units OC, OS1 and OS2 in one refrigerant circuit system are automatically detected.
OC, OS1 and OS2 are ranked in descending order of capacity. If units are the same capacity, they are ranked in ascending order
of their address.
2. Address should be set to Indoor units, LOSSNAY and system controller.
3. M-NET power is supplied by the Outdoor unit at TB3, while Indoor unit and ME remote controller consume the M-NET power for transmission
use. The power balance is needed to consider for long M-NET wiring. Details refer to 11-3. "System configuration restrictions".
4. When the PAR-CT01MA series, PAR-FS01MA series, PAR-4"x"MA series, or PAR-3"x"MA series ("x" represents 0 or later) is connected to a
group, no other MA remote controllers can be connected to the same group.
MEES23K040
PUHY
OS2
OC
TB7
TB7
53
91
CN40
CN41
CN40
CN41
DipSW5-1
DipSW5-1
ON
ON
TB3
TB3
TB3
Group 1
Indoor unit
01
TB5
TB15
TB5
202
*1
SRU
*3
SC
*1
Wireless R/C
Group 31
Group 32
Indoor unit
41
TB5
TB15
TB5
*1
SRU
*3
ME R/C
*1
Wireless R/C
PUHY
OS1
OC
TB7
TB7
92
97
CN40
CN41
CN40
CN41
DipSW5-1
DipSW5-1
ON
ON
TB3
Group 2
02
03
TB15
TB5
TB15
TB2
Transmission Booster
MA R/C
LOSSNAY
Interlocked with
M-NET address 42
42
43
TB5
142
Group 21
30
TB3
TB5
TB15
PAC-SF46EPA-G
MA R/C
(Main)
Group 33
Group 34
44
45
TB5
TB15
TB5
TB15
MA R/C
MA R/C
(Main)
Y-Series
MA R/C
(Sub)
MA R/C
(Sub)
174

Advertisement

Table of Contents
loading

Table of Contents