3. Disable direct hazards/Safety regulations.
3.3 Disconnect the high-voltage battery
In case of emergency, disconnect or cut the service interlock connector cable (A) to isolate the high-voltage of the battery.
a. Remove the service interlock connector
(A) located at the engine compartment.
WARNING
Before engaging in emergency response procedures, ensure the vehicle is disabled and wait for more than 5 minutes to
allow the capacitor in the high-voltage system to discharge to avoid electrocution.
Exposed cables or wires may be visible inside or outside the vehicle. To prevent injury or death due to electrical shock,
never touch the wires or cables before disabling the system, to prevent injury or death due to electrical shock.
Failure to follow any of these instructions may result in serious injury or death by electrocution.
WARNING
SRS components may remain powered and active for up to 3 minutes after the 12V electrical system is shut off or
disabled. Disconnect the battery cable and wait for at least 3 minutes before beginning work.
Failure to follow any of these instructions may result in serious injury or death from accidental deployment of the airbag
system.
Electrocution risk
Explosive risk
b. If the Service Interlock connector cannot
be disconnected, cut the wire attached the
yellow warning label.