The system will attempt to fill and/or drain ballasts to reach a static pitch, roll and amplitude setpoint. If pitch or
roll setpoints cannot be achieved, a pop-up will occur indicating this to the driver (AutoWake will remain in this
state).
(6) Static AutoWake Achieved: This will occur when:
Boat is turned on
AutoWake is turned on
Actual speed is less than 3mph
Pitch, roll and amplitude values match their respective setpoints.
If pitch or roll setpoints cannot be achieved, a pop-up will occur indicating this to the driver and AutoWake will
remain in Static AutoWake Active state. If pitch and roll are achieved and amplitude is as close as possible to
setpoint, the AutoWake system will go to this state.