Hitachi RAS-14EH1 Service Manual page 70

Hide thumbs Also See for RAS-14EH1:
Table of Contents

Advertisement

OUTDOOR UNIT
Remove the compressor connector.
1/ 2/ IPM (Intelligent Power Module)
3/ Service Switch
4/ Self-Diagnosis Lamp
If your first attempt
fails, wait 3 minutes
(for the unit to re-
start) and check the
self-diagnosis lamp
status again.
With the unit set in the operating
state, press the start/stop
button.
Does the unit operate for
approximately 2 seconds (the
LD303 coming on) and then
stop due to a failure of switching
(the lamp blinking 4 times)?
Check outdoor electrical parts.
– 68 –
Yes
No
• Check the drive
circuit (IPM) using
the PRD checker.
• Check the position
sensor circuit.
Normal
Check the refrigerating
cycle.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rac-14eh1

Table of Contents