The Purpose Of The Bullet ® Dcx Nh; Design - yellow jacket BULLET DCX NH3 Operation And Maintenance Manual

Vacuum pump
Table of Contents

Advertisement

The Purpose of the BULLET
The BULLET
DCX NH
®
ro tary vane design (Fig.1) that increases
efficiency and speeds pump down to 25
microns.
The pump lowers the internal pressure of
a refrigeration system until moisture boils
into a vapor. As the moisture is vaporized,
it is evacuated by the pump to help dehy-
drate the system. Most technicians try to
achieve between 250 and 1000 microns.
A manometer or electronic vacuum gauge
are the only ways to monitor evacua-
tion progress. Manometer readings are
approximate in inches of mercury. Only
an electronic vacuum gauge is accurate
enough to show when you reach the
desired mi cron range.
As the chart shows, only an electronic
gauge reads fine differences to provide
assurance that the vacuum is low enough
to boil the greatest possible amount of
moisture.
Boiling Temp
Inches
of Water
Mercury
212°F (100°C)
151°F (66°C)
101°F (38°C)
78°F (26°C)
35°F (2°C)
1°F (17°C)
29.882
-50°F (-46°C)
29.919
How One Small Drop Dampens Your
Profits.
A small drop of moisture can hurt your
profits and reputation.
During new system set-up, protective caps
are removed admitting moisture and air
into system components.
DCX NH
®
Pump is a 2-stage
3
Microns
0
760,000
22.05
200,000
27.95
50,000
28.95
25,000
29.72
5,000
1,000
50

Design

3
First stage exhausts into the intake of the second stage
similar to two single stage pumps connected together.
If air – a non-condensable – remains in the
system, it collects on the high side reduc-
ing system efficiency. This causes a rise
in head pressure. The discharge valve gets
hotter than normal and organic solids form
causing compressor failure.
Moisture in the system can form ice which
closes off openings in expansion valves
and cap tubes, and prevent adequate
cooling.
Ultimately moisture and air can produce
acids and sludge which could cause
in -warranty failures.
During service and parts replacement,
the same contaminants get in again, and
you could be called back for repairs by a
dissatisfied customer.
Moisture and air can even enter through
system leaks. And as the moisture in
the air increases, so does the amount of
contamination. The higher the humidity,
the bigger your problem.
A vacuum pump "pulls" air and moisture
out of the system before the system is
damaged. The higher and more complete
the vacuum, the more moisture is removed.
That's why your BULLET
specifically engineered for high vacuums
of 25 microns or better.
Fig.1
DCX NH
Pump is
®
3
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bullet x nh3935309353393539

Table of Contents