  • Page 1 SuperEvac Vacuum Pump ® Operation and Maintenance Manual Models: 9354x, 9356x, 9358x, 9359x...
  • Page 2: Table Of Contents

    Warranty and Service....................12 Important Notices to Purchaser Check for damage immediately. The CARRIER ALONE is responsible for handling and settling your claim. Ritchie Prior to shipment, all YELLOW JACKET ® Engineering will cooperate in assessing SuperEvac vacuum pumps are com- ™...
  • Page 3: Features Of Your New Pump

    Features of Your New Pump 1. Male flare pump intake. Tethered cap 5. Opening the ballast allows fresh air to stays with unit. Large diameter hose enter the cartridge and keep vapors suggested for maximum pull down. from combining with the oil. Vapors escape harmlessly through the exhaust 2.
  • Page 4: Design

    The Purpose of the SuperEvac Design ™ The SuperEvac Pump is a 2-stage ro tary vane design (at right) that increases efficiency and speeds pump down to 15 microns. The pump lowers the internal pressure of a refrigeration system until moisture boils into a vapor.
  • Page 5: Important Steps Of Initial Start-Up

    10-15 seconds. voltage. 6. When turning pump off, open intake 2. Remove oil fill cap on pump cover. Fill fitting until vacuum indicator gauge with YELLOW JACKET SuperEvac ™ ® reads zero to break vacuum just prior Pump Oil until oil level is even with oil to shut-off.
  • Page 6 If you think there is excessive mois- 8. Use a SuperEvac System I, II or III to ture, blow out the AC&R system with dry decrease vacuum nitrogen wherever possible. This reduces time by over 50%. the amount of contaminants that must These systems be “pulled”...
  • Page 7: Basic Troubleshooting

    Basic Troubleshooting • Your SuperEvac pump features a Four Most Common Comments on ™ heavy-duty high torque motor for cold Pump Return Paperwork: weather starting, but dirty oil makes 1. “Will not pump.” This usually means starting more difficult, causing unnec- essary wear on your unit.
  • Page 8: Diagnostic Chart

    SuperEvac Digital Vacuum Gauges ™ The YELLOW JACKET Omni Digital Vacuum Gauge is an easy- ® ™ to-use, compact vacuum gauge that is loaded with features for the price. Easily set target vacuum level and the OMNI and will give audio and visual signals when that level is reached.
  • Page 9 Diagnostics Chart continued Condition Pump Area Possible Problem Solution Damaged motor Repair or replace Motor Stalled Damaged pump Replace/call factory hot/cold Closed intake/gas ballast on Open intake fitting and gas pumps ballast Pump Won’t Ultimate of pump Start Shorter extension cord Low voltage does not meet mfg.
  • Page 10: Replacement Parts

    Replacement Parts PUMP # PUMP # PUMP # PUMP # 93514 93515 93511 93590 93516 93596 9358x 93592 93594 9356x 93595 9354x 93598 4 CFM 6 CFM 8 CFM 11 CFM (113 L/M) (170 L/M) (227 L/M) (311 L/M) Pump Oil Cover 1.
  • Page 11 PUMP # PUMP # PUMP # PUMP # 93514 93515 93511 93590 93516 93596 9358x 93592 93594 9356x 93595 9354x 93598 4 CFM 6 CFM 8 CFM 11 CFM (113 L/M) (170 L/M) (227 L/M) (311 L/M) Mounting Body 12. Complete body (individual part below) 92953 92953 92954...
  • Page 12: Warranty And Service

    You will receive personal help to determine if the problem can be solved without sending your pump to the factory and taking it out of service. Ritchie Engineering Company, Inc. YELLOW JACKET Products Division ® 10950 Hampshire Avenue South Bloomington, MN 55438-2623 USA E-mail: custserv@yellowjacket.com...