High-Vibration Application Connections - National Instruments NI-9375 Getting Started

Hide thumbs Also See for NI-9375:

Advertisement

2. Press a wire into the open connector terminal.
3. Remove the screwdriver from the activation slot to clamp the wire into place.
Connecting Wires to the NI-9375 with Push-in Style
Spring Terminal (Black/Orange Connector)
What to Use
NI-9375 spring terminal black/orange connector
0.14 mm to 1.5 mm (26 AWG to 16 AWG) copper conductor wire with 10 mm
(0.394 in.) of insulation stripped from the end
Ferrules (optional)
What to Do
Refer to the following table for how to insert a wire into a terminal depending on
what type of wire you are using or if you are using a ferrule.
Option
When using a solid wire or stranded wire with a
ferrule
When using a stranded wire without a ferrule
Note
connecting more than one wire to a single terminal.

High-Vibration Application Connections

If your application is subject to high vibration, NI recommends that you use the
NI-9940 backshell kit to protect connections to the NI-9375 with spring terminal.
10
ni.com
You must use 2-wire ferrules to create a secure connection when
Description
Push the wire into the terminal when using a
solid wire or stranded wire with a ferrule
Press the push button and then push the wire
into the terminal
NI-9375 Getting Started

Advertisement

loading

This manual is also suitable for:

781030-01