Advertisement

Quick Links

MANUALE D'USO E MANUTENZIONE
ISTRUZIONI ORIGINALI - ITALIANO
SX-RANGE
GE SX- 7554 YDT
• Gruppo Elettrogeno
• Stromerzeuger
• Generating Set
• Grupo Gerador
• Groupe Electrogene
• Генераторная Установка
• Grupos Electrógenos
• Stroomaggregaten
M A D E
I N
• Skupina generátoru
I T A L Y
lingua
Codice
Code
Code
Codigo
CE0P60U39003
Kodezahl
Código
Код
Code
Kód
Edizione
Edition
Édition
Edición
01.2020
Ausgabe
Edição
Издание
Editie
Edice

Advertisement

Table of Contents
loading

Summary of Contents for Mosa GE SX-7554 YDT

  • Page 1 lingua MANUALE D’USO E MANUTENZIONE ISTRUZIONI ORIGINALI - ITALIANO Codice SX-RANGE Code Code Codigo GE SX- 7554 YDT CE0P60U39003 Kodezahl Código Код Code Kód Edizione Edition Édition • Gruppo Elettrogeno • Stromerzeuger • Skupina generátoru Edición 01.2020 Ausgabe • Generating Set •...
  • Page 3: Table Of Contents

    INDEX 0. GENERAL INFORMATION M1.1 INTRODUCTION ........................PAG. 4 M1.4 CE MARK ..........................PAG. 5 SYMBOLS AND SAFETY PRECAUTIONS ................... PAG. 6 WARNINGS ..........................PAG. 7 M2.1 M2.5 SAFETY RULES ........................PAG. 8 1. GENERAL INFORMATION OF THE MACHINE DESCRIPTION OF THE MACHINE ....................PAG. 10 RECORDING DATA ........................
  • Page 4: Introduction

    INTRODUCTION Dear Customer, The Manufacturer shall not be liable for ANY USE OF THE PRO- We wish to thank you for having bought a high quality set. DUCT OTHER THAN THAT PRECISELY SPECIFIED IN THIS Our sections for Technical Service and Spare Parts will work at MANUAL and is thus not liable for any risks which may occur as best to help you if it were necessary.
  • Page 5: Ce Mark

    CE MARKING GENERATING SETS Any of our product is labelled with CE marking attesting its conformity to appliable directives and also the fulfillment of safety requirements of the product itself; the list of these directives is part of the declaration of conformity included in any machine standard equipment.
  • Page 6: Symbols And Safety Precautions

    SYMBOLS AND SAFETY PRECAUTIONS SYMBOLS IN THIS MANUAL DANGER - The symbols used in this manual are designed to call your GENERAL ADVICE - If the advice is not respec- attention to important aspects of the operation of the machine ted damage can happen to persons or things.
  • Page 7: Warnings

    WARNINGS FIRST AID. In case the operator shold be sprayed by accident, from corrosive liquids a/o hot toxic gas or whate- ver event which may cause serious injuries or death, predispose the first aid in accordance with the ruling labour accident standards or of local instructions.
  • Page 8: Safety Rules

    SAFETY RULES GENERATING SETS - LIGHTING TOWERS GENERAL SAFETY INSTRUCTIONS • Do not replace the tires with types different from the original + NOTE: the information contained in this manual are ones. subject to change without notice. • Check that the brakes and the optical signaling of the trailer are working properly.
  • Page 9 SAFETY RULES GENERATING SETS - LIGHTING TOWERS 2.5.1 SAFETY PRECAUTIONS DURING MAINTENANCE ADDITIONAL PRECAUTIONS FOR LIGHTING TOWERS • Make use of qualified personnel to carry out maintenance and troubleshooting. ATTENTION • It is mandatory to stop the engine before performing any maintenance on the machine.
  • Page 10: Description Of The Machine

    DESCRIPTION OF THE MACHINE The generating set is a unit which transforms the mechanical energy, generated by combustion engine, into electric energy, through an alternator. The model GE SX-7554 is a compact diesel generating set, is easily transported using a trolley. The unit is composed by: a base, a tank, an engine/alternator unit fixed on the base by elastic dampers, a roll-bar, with central hook for an easy and sure lifting, canopy realized in one piece only to permit an easy maintenance (replacement filter air, oil and fuel)..
  • Page 11: Recording Data

    RECORDING DATA The manual is for the range of machines indicated on the front cover. With the scope to facilitate the search of the spare parts and maintain information of the bought machine, is necessary to record some data. Please write the requested data inside the squares to side: Model of machine Serial number of the machine Serial number of the engine...
  • Page 12: Machine Unpacking

    MACHINE UNPACKING NOTE Be sure that the lifting devices are: correctly mounted, adequate for the weight of the machine with it’s packaging, and conforms to local rules and regulations. When receiving the goods make sure that the product has not suffered damage during the transport, that there has not been rough handling or taking away of parts contained inside the packing or in the set.
  • Page 13: M4 Transport And Displacements Covered Units

    TRANSPORT AND HANDLING COVERED UNITS NOTE Transportation must always take place with the engine off, electrical cables and starting battery disconnected and fuel tank empty. Be sure that the lifting devices are: correctly mounted, adequate for the weight of the machine with it’s packaging, and conform to local rules and regulations.
  • Page 14: Installation

    INSTALLAZIONE - INSTALLATION - INSTALLATION INSTALACIÓN - LUFTZIRKULATION - INSTALAÇÃO УСТАНОВКА - INSTALLATIE M1.4...
  • Page 15: M2.6 Installation And Advice

    InstallatIon advIces environMental conditions General installation criteria Installation of a genset has to be planned by qualified and trained technicians, it has to be carried out by a competent attention organization with qualified personnel and proper equipment. attention Open gensets (SKID) have to be located in an area pro- tected from rain, snow, high humidity and direct exposure to the sun.
  • Page 16 In order to avoid potentially dangerous situations, area surrounding genset should be isolated so that unauthorized people will not be able to get close to the unit. Even if MOSA Engine and alternator when in operation produce heat: gensets are manufactured according to electromagnetic •...
  • Page 17 InstallatIon advIces 2.6.2 Sample of outdoor installation with shelter Floor should be levelled and suitable to sustain genset weight. Thresholds on doors and openings should have a barrier in or- der to avoid liquids leaking. In case it is not possible to provide a door with a barrier, the genset should have a collection base appropriate for the quantity of liquid it contains, in any case dimensions of collection base must be in accordance to the...
  • Page 18 InstallatIon advIces 2.6.3 For open gensets installed indoors, we recommend: Electro ventilator capacity can be calculated as follows: • The dimensions of the air outlets be such that they have at least the same area of the radiator; Transmitted heat [Kcal/h] •...
  • Page 19: Set-Up For Operation

    SET-UP FOR OPERATION (DIESEL ENGINE) AIR COOLED SYSTEMS BATTERY WITHOUT MAINTENANCE (WHERE IT IS ASSEMBLED) FUEL The supplied battery is generally ready for use. ATTENTION Connect the cable + (positive) to the pole + of the battery, by properly tightening the clamp. Stop engine when fueling.
  • Page 20: Earthing

    Earthing Earthing WithOUt grOUnD FaULt intErrUPtEr Earthing With isOmEtEr The protection against electric shock from contact indirect is Machines equipped with insulation resistance monitor allow intentionally not to connect the ground terminal PE (12) to an ensured by the “electrical separation” with equipotential bonding earthing system.
  • Page 21: Starting And Stopping

    STARTING AND STOPPING THE ENGINE Check daily NOTE Do not alter the primary conditions of regulation and do not touch the sealed parts. START The engine is started and stopped by operating directly on the InteliNANO PLUS controller. Consult the controller manual for a complete understanding of its performance.
  • Page 22: Components Of Front Panel

    COMPONENTS OF FRONTAL PANEL Pos. Description Function Thermal-magnetic circuit General switch for the gen-set. breaker It protects both gen-set and related electrical circuit from over current / short circuit. Ground fault interrupter Device for protection against not-direct contacts. (30 mA) Insulation monitoring Protection device against indirect contact for IT systems (GE neu- tral not to ground).
  • Page 23: M37

    UsE As gEnErAtor OPERATING CONDITIONS WARNING POWER The electrical power expressed in kVA on an electricity- It is absolutely forbidden to connect the unit to the public generating group is the available output power to the reference mains and/or another electrical power source . environmental conditions and nominal values for: voltage, frequency, power factors (cos ϕ).
  • Page 24 UsE As gEnErAtor 37.1 The frequency, and therefore the number of motor revolutions, SINGLE-PHASE LOADS is maintained constant by the motor’s speed regulation system. Power to monophase utilities by means of three-phase Generally, this regulator is of a mechanical type and presents generators requires some operating limitations.
  • Page 25 UsE As gEnErAtor 37.2 DIFFERENTIAL SWITCH USAGE WITH EAS AUTOMATIC START-UP PANEL The differential switch or differential relay guarantee protection The electricity-generating group in combination with the EAS against indirect contacts due to malfunction currents towards the automatic start-up panel forms a unit for distributing electrical ground.
  • Page 26: Protection - Insulation Monitoring

    ENGINE PROTECTION INSULATION MONITORING 39.10 LEGEND: NOTE Adjustment of Alarm threshold Set-alarm dip-switches Led, pre-allarm indication DO NOT INTERVENE ON THE SETTING OF THE PROTEC- TION SWITCH. BEFORE USING THE MACHINE CHECK Led , power indication Led Alarm indication THE ON WARNING LAMP LIGHTING. Test push-button Reset push-button Adjustment of- PRE-ALARM threshold...
  • Page 27: Remote Control

    REMOTE CONTROL TCM 35 38.6 MAKE SURE  The selector LOCAL START/REMOTE START (I6) of the generating set must be switched on LOCALSTART (with EP6). The coupling of the TCM 35 with the generating set, ready for remot starting, permits to work far from the set itself. The remote control is connected to the front plate (X1), and/or rear plate, with a multiple connector.
  • Page 28: M40.2

    TROUBLESHOOTING 40.2 Problem Possible cause Solution ENGINE The motor does not start up Start-up switch (I6) (where it is assembled) in incor- Check position rect position Emergency button (L5) pressed Unblock Preheating (where it is assembled) Lacking or insufficient preheating phase for sparkplugs.
  • Page 29 TROUBLESHOOTING 40.2.1 Problem Possible cause Solution GENERATOR Absence of output voltage Voltage switch in position 0 Check position Voltage switch faulty Check connections and working of the switch, repair or replace Protection tripped due to overload Check the load connected and diminish Differential protection device tripped.
  • Page 30: Maintenance

    MAINTENANCE WARNING ● Have qualified personnel do maintenance and troubleshooting work. ● Stop the engine before doing any work inside the machine. If for any reason the machine must be operated while working inside, pay at- tention moving parts, hot parts (exhaust manifold and muffler, etc.) electrical parts which may be unprotected when the machine is open.
  • Page 31 MAINTENANCE 43.1 ATTENTION • Maintenance operations on the electricity-generating group prearranged for automatic operation must be carried out with the panel in RESET mode. • Maintenance operations on the installation’s electrical panels must be carried out in complete safety by cutting off all external power sources: ELECTRICAL POWER, GROUP and BATTERY.
  • Page 32: M45 Storage And Cast Off

    STORAGE And diSASSEmblE STORAGE DISASSEMBLE + Have qualified personnel disassemble the machine and In case the machine should not be used for more than 30 days, dispose of the parts, including the oil, fuel, etc., in a correct make sure that the room in which it is stored presents a suitable manner when it is to be taken out of service.
  • Page 33: Technical Data

    TECHNICAL DATE GE SX-6500 YDT (AVR) GENERATOR *Stand-by three-phase power 6.5 kVA (5.2 kW) / 400 V / 9.4 A *PRP three-phase power 5.7 kVA (4.6 kW) / 400 V / 8.2 A *PRP single-phase power 3.5 kVA (kW) / 230 V / 15.2 A Frequency 50 Hz Cos ϕ...
  • Page 34 DIMENSIONI - DIMENSIONS - DIMENSIONS - DIMENSIONES ABMESSUNGEN - DIMENSÕES - РАЗМЕРЫ - AFMETINGEN 2.7.1 1035...
  • Page 36 MOSA div. della BCS S.p.A. Viale Europa, 59 20090 Cusago (Milano) Italy Tel.+39 - 0290352.1 Fax +39 - 0290390466 www.mosa.it...

This manual is also suitable for:

Ce0p60u39003

Table of Contents