Download Print this page

Intermatic PE700 Series Programming Manual page 7

Smart wi-fi timer

Advertisement

PE700 Series Smart Wi-Fi Timer
Overrides are generated from the following inputs:
• Override Button (Toggle - On/High, Off/Low)
Override buttons are tied directly to their corresponding circuit.
|
L1 -> C1
L2 -> C2
L3 -> C3
In the case where Circuits 1 and 2 are combined to handle larger loads:
|
L1 -> C1 & C2
L2 -> Does nothing
L3 -> C3
• Discrete Digital Input (Configurations Below)
Switch (Toggle)
|
Presence Sensor (Occupancy On/High\Vacancy Off/Low)
|
Standard Photocontrol (On/High when light level is below X Lux, Off/Low
|
when light level is greater than X Lux)
• Mobile (While connected locally, Bluetooth only.
• Alexa or Google voice assistants.
Types of Overrides:
The following types are on a per Circuit/Output basis. Meaning the override
type is stored in Output configuration.
Normal:
• [Override Off to On] When an Output/Circuit is Off and an override is
issued, the Output/Circuit is driven On and an override timer is started.
When the Override Timer expires, the Output/Circuit is driven Off.
• [Override On to Off] If an Output/Circuit is On and the Output/Circuit is
overridden Off, the Output/Circuit is driven Off, regardless of what the
schedule would command the Output/Circuit.
Extended:
• [Override Off to On] When an Output/Circuit is Off and an override is
issued, the Output/Circuit is driven On and an override timer is started. The
Output/Circuit will remain On for the duration of the override. When the
Override Timer expires, the firmware will check the calculated schedule
output state, if the calculated schedule state is On, the firmware leaves the
Output/Circuit On. If the calculated schedule state is Off, the firmware turns
the Output/Circuit Off.
• [Override On to Off] If the Output/Circuit is On and an override is issued,
the Output/Circuit will remain in the On state for the duration of the Override
Time. When the override timer expires, device will evaluate the schedule to
determine whether to leave the Output/Circuit On or to turn Off based on the
schedule. If the schedule is Off at the end of the override, the Output/Circuit
is switch Off. If the Schedule is On at the end of the override period, the
Output/Circuit will remain On.
• Enable/Disable Sensor Overrides with Schedule Event
• Discrete sensor override inputs can be enabled or disabled using a schedule
event. The enable/disable feature is only active during Auto Mode. Discrete
overrides will be enabled when in Manual or Service Modes.
• If a Circuit/Output is actively overridden by an Input configured as a Light
Sensor and the Light Sensor Input is disabled by an Enable/Disable Schedule
Event, the override is terminated immediately.
• When a discrete override input is configured as a Switch, the input can't be
disabled.
• If an Input is configured as a Presence Sensor, the Override Time property is
not used. A Circuit/Output overridden by a Presence Sensor will not time out
using the internal Override Time property. If a Circuit/Output is actively
overridden by a Presence Sensor and the Presence Sensor Input is disabled
by the schedule, the active override isn't terminated until the Presence
Sensor no longer detects occupancy and times out.
INTERMATIC INCORPORATED | 1950 Innovation Way, Suite 300 | Libertyville, Illinois 60048 | www.Intermatic.com
Programming Guide: Models PE723P, PE733P
• If both a Presence Sensor and Light Sensor override inputs are driving a
common Circuit/Output(s), the Presence Sensor will keep the Circuit/Output
overridden On while presence is detected.
• In the event a user combines Circuit 1 and Circuit 2, discrete Input 2 will no
longer point to Circuit/Output 2, as it will no longer point to a Circuit/Output.
• A schedule Event to enable/disable a discrete sensor override input:
Applies to override inputs configured as presence and light sensors
|
Time (Specific, Dusk or Dawn)
|
Discrete Input(s) (DI1, DI2, DI3)
|
One input, combination of any, or all 3
|
Enable or Disable
|
• Override Time is a settable property by a mobile app user. Override time
value is used for all overrides except for Inputs configured for Presence and
Light Sensors.
• If Mode is changed from Auto to Manual or Service modes while an override
is active, the override is cancelled, and the Circuits/Outputs will remain in
the current On/Off state
.
Firmware Upgrade (OTA)
Firmware upgrades can be initiated by a user when connected locally or
remotely through the Intermatic Connect Cloud. Firmware upgrades can also be
automatically scheduled from the cloud and user preferences.
User can select how and when an OTA can be executed.
• Automatic when upgrade is made available
Device will determine when a good time to perform an OTA. Conditions for
|
performing a cloud-connected Automatic Update are as follows:
All relays de-energized OR ...
24 hours have passed where 1 or more relays have been continuously
energized AND it's between 3:00-3:59am.
... whichever comes first.
• User commanded OTA (local OTA)
On demand
|
User starts OTA
|
1.2 Mobile Phones/Tablets Supported
Apple
• Apple iPhone that supports the latest version of iOS and minus one for the
iPhone and iPad. (Today that would be iOS 17 and 16)
• Apple iPad. Ascend App supports iPad
Android
• Android OS 9 or newer is supported
300PS10323
7

Advertisement

loading

This manual is also suitable for: