Bleeding the hydraulic system
WARNING
Use personal protective equipment!
Pit jack is unloaded, freely accessible and cleaned!
The pit jack is fully retracted and load-free!
The pit jack must be disconnected from the compressed air supply.
C
D
1
Check the oil level and top up with hydraulic oil if necessary. The target fill
level of the hydraulic oil is in the center of the oil sight glass when retracted.
66
Bleeding block
B
A
BA550001-en