SICK RFH5 Operating Instructions Manual
SICK RFH5 Operating Instructions Manual

SICK RFH5 Operating Instructions Manual

Rfid read/write device (hf)
Hide thumbs Also See for RFH5:

Advertisement

Quick Links

O P E R A T I N G I N S T R U C T I O N S
RFH5xx
RFID read/write device (HF)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RFH5 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SICK RFH5

  • Page 1 O P E R A T I N G I N S T R U C T I O N S RFH5xx RFID read/write device (HF)
  • Page 2 This work is protected by copyright. Any rights derived from the copyright shall be reserved for SICK AG. Reproduction of this document or parts of this document is only permissible within the limits of the legal determination of Copyright Law. Any modi‐...
  • Page 3: Table Of Contents

    Operation.................... 33 Operating options..................Optical status indicators................Operation via IO-Link................8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 4 CONTENTS Maintenance..................55 Maintenance plan..................Cleaning..................... Troubleshooting................. 56 10.1 Overview of Potential Errors and Faults..........10.2 SICK service....................10.3 Repairs...................... 10.4 Returns...................... 10.5 Device exchange with transmission of the current configuration data. Decommissioning................58 11.1 Disposal..................... Technical data..................59 12.1 Features....................
  • Page 5: About This Document

    … highlights useful tips and recommendations as well as information for efficient and trouble-free operation. 8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx...
  • Page 6: Further Information

    Further information More information can be found on the product page. The page can be accessed via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label. {S/N} corresponds to the serial number of the product, see type label (if indicated).
  • Page 7: Safety Information

    Technical Information RFH5xx Regulatory Compliance. SICK AG assumes no liability for losses or damage arising from the use of the product, either directly or indirectly. This applies in particular to use of the product that does not conform to its intended purpose and is not described in this documentation.
  • Page 8: Improper Use

    The device must not be used in explosion-hazardous areas, in corrosive environ‐ ments or under extreme environmental conditions. • Any use of accessories not specifically approved by SICK AG is at your own risk. WARNING Danger due to improper use! Any improper use can result in dangerous situations.
  • Page 9: Modifications And Conversions

    Modifications and conversions to the device may result in unforeseeable dangers. Interrupting or modifying the device or SICK software will invalidate any warranty claims against SICK AG. This applies in particular to opening the housing, even as part of mounting and electrical installation.
  • Page 10 Device with fixed cable: Damage to the cable outlet or cable itself O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309/1KDE/2023-12-19 | SICK Subject to change without notice...
  • Page 11: Product Description

    Conformity symbol for Europe Part number Date of manufacture (year, calendar week) 8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 12 510: max. 60 mm (Short Range) 515: max. 80 mm (Short Range) O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309/1KDE/2023-12-19 | SICK Subject to change without notice...
  • Page 13 Reading distance achieved depends on dimensions and quality of the transponder. Including clamping bracket 8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx...
  • Page 14: Product Characteristics

    4 x LED, multi-colored (process feedback) IO-Link connection (male connector, M12, 4-pin, A-coded) O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309/1KDE/2023-12-19 | SICK Subject to change without notice...
  • Page 15 4 x LED, multi-colored (process feedback) IO-Link connection (male connector, M12, 4-pin, A-coded) 8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 16 POWER LED, display color green Cap with integrated antenna O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309/1KDE/2023-12-19 | SICK Subject to change without notice...
  • Page 17 Reading field width in mm (inch) Reading distance in mm (inch) 8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 18 The delivery of the device includes the following components in the packaging: O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309/1KDE/2023-12-19 | SICK Subject to change without notice...
  • Page 19 Convenient operation • Device configuration for demonstrating the operating principle of and configuration the device in the SICK SiLink2 IO-Link master with SOPAS ET config‐ uration software • Device configuration for operational use via the system control (PLC) using an IO-Link master and the type-specific IO-Link device description file (IODD) of the RFH5xx in the configuration tool of the •...
  • Page 20 This transponder can only be read (UID & user memory) O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309/1KDE/2023-12-19 | SICK Subject to change without notice...
  • Page 21: Transport And Storage

    For storage periods of longer than 3 months, check the general condition of all components and packaging on a regular basis. 8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx...
  • Page 22: Mounting

    O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309/1KDE/2023-12-19 | SICK Subject to change without notice...
  • Page 23 RFH515: mount the device using the supplied clamping bracket. Optional SICK brackets RFH505 or RFH510: the device can be installed using an optional SICK bracket or a customer-specific bracket. SICK offers prefabricated brackets which are optimally suited for mounting the device in a wide range of applications.
  • Page 24: Mounting Location

    MOUNTING NOTE Dimensional drawings for SICK brackets and, if applicable, mounting instructions can be found online at: www.sick.com To do so, enter the 7-digit part number of the bracket in the search field. ► User-supplied brackets A user-supplied bracket should meet the following requirements: Stable mounting device ■...
  • Page 25 8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx...
  • Page 26 Figure 13: Optimal alignment of the transponders for a reliable read and write process. Cap with antenna RFH515 O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309/1KDE/2023-12-19 | SICK Subject to change without notice...
  • Page 27 Figure 14: Optimal alignment of the transponders for a reliable read and write process. Cap with antenna 8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx...
  • Page 28: Electrical Installation

    DIN VDE 0298 (Part 4) and/or DIN VDE 0891 (Part 1). O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309/1KDE/2023-12-19 | SICK Subject to change without notice...
  • Page 29: Wiring Instructions

    You will find recommended connecting cables and associated technical data on the product page. The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label. {S/N} corresponds to the serial number of the product, see type label (if indicated).
  • Page 30: Pin Assignments Of Electrical Connections

    IO-Link communication / digital output 1 Prerequisites • Use SICK IO-Link standard cables for the specified ambient temperature range. NOTE You will find the technical data for the cables on the product page. The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label.
  • Page 31: Commissioning

    SiLink2 Master RFH5xx Transponder SIG200 (IO-Link Master) Transponder Prerequisites: • SICK SiLink2 IO-Link master with wall plug and enclosed USB cable • IO-Link device (RFH5xx) • IO-Link cable (male/female connector) • Computer (Windows) with installed SOPAS ET configuration software Certain functions (e.g., Edit parameters) require you to be logged in to the device ( Device >...
  • Page 32 SIG200 (IO-Link Master) Transponder Prerequisites: • IO-Link master, z. B. SICK SIG200, connected to the PLC via fieldbus • Common PLC configuration tool, if necessary function block for the device instal‐ • Type-specific IODD of the device (RFH5xx) for transfer to the PLC Procedure Connect the device (RFH5xx) to the voltage-free IO-Link master via IO-Link.
  • Page 33: Operation

    The transponder is outside the reading field. RSSI = Received Signal Strength Indication. 8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 34 The transponder is within the maximum range of the reading field. O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309/1KDE/2023-12-19 | SICK Subject to change without notice...
  • Page 35: Operation Via Io-Link

    The IO-Link devices communicate with the superior control systems using an IO-Link master. 8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 36 To ensure that the IO-Link sensor can be easily integrated into the control program, SICK also provides function blocks for many control systems. These function blocks facilitate, among other things, the reading and writing of the individual sensor parame‐...
  • Page 37 Process Data In (PDI) Valid for modes: Read UID, (Auto)-Read and (Auto)-Write. 8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 38 1: Command run, but error 0: No transponder detected 1: Transponder detected O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309/1KDE/2023-12-19 | SICK Subject to change without notice...
  • Page 39 UserMemory 0-27 Type [Subindex] Unsigned integer 224 [8 ... 35] 8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 40 Lock 16 (0x10) Vendor name String 16 byte SICK AG O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309/1KDE/2023-12-19 | SICK Subject to change without notice...
  • Page 41 Locate Device ro = read only, wo = write only, rw = read/write 8.3.2.2 SICK device specific SIO mode parameters In addition to data exchange in IO-Link mode, the device can also switch in SIO mode (standard I/O).
  • Page 42 O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309/1KDE/2023-12-19 | SICK Subject to change without notice...
  • Page 43 66 (0x42) RF configuration Record 4 Byte RF configuration 8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 44 For 1:1 exchange between a read device and transponder ° O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309/1KDE/2023-12-19 | SICK Subject to change without notice...
  • Page 45 If the device is operated in SIO mode, an alarm can also be used as a source for the SIO mode. 8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx...
  • Page 46 1 (0x01) RFID standard compati‐ Bit (896) 32 Byte 13.56  bility MHz, ISO15693 O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309/1KDE/2023-12-19 | SICK Subject to change without notice...
  • Page 47 32 Bit 4 (0x04) RFU Bit (32) 32 Bit 8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 48 Number of memory blocks: 2 blocks = 8 bytes Starting at (address/offset): Block number 0 O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309/1KDE/2023-12-19 | SICK Subject to change without notice...
  • Page 49 Number of memory blocks (2 blocks = 8 bytes) 0x00 Reserved 0x00 Address (offset) 8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 50 To switch from another mode to this one, the “Start” bit must be 1. ✓ Response in the PDI: O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309/1KDE/2023-12-19 | SICK Subject to change without notice...
  • Page 51 Bit 4 (Reserved): 0 Bit 5 … 7 (Command): 100 8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 52 RSSI (variable value, depending on trans‐ ponder and read) 0x01 Address (offset) O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309/1KDE/2023-12-19 | SICK Subject to change without notice...
  • Page 53 The codes can be read out by the PLC or using the SOPAS ET configuration software. 8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx...
  • Page 54 App General Error General error O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309/1KDE/2023-12-19 | SICK Subject to change without notice...
  • Page 55: Maintenance

    Use a dry cloth or an industrial vacuum cleaner for cleaning. Do not use cleaning agents. 8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx...
  • Page 56: Troubleshooting

    SICK AG. Fast replacement of a device by the customer is, however, possible. If a fault cannot be rectified, contact the SICK Service department. To find your ► agency, see the final page of this document.
  • Page 57: Repairs

    TROUBLESHOOTING 10.3 Repairs Repair work on the device may only be performed by qualified and authorized personnel from SICK AG. Interruptions or modifications to the device by the customer will invalid‐ ate any warranty claims against SICK AG. 10.4 Returns Only send in devices after consulting with SICK Service.
  • Page 58: Decommissioning

    Separate the recyclable materials by type and place them in recycling containers. ■ O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309/1KDE/2023-12-19 | SICK Subject to change without notice...
  • Page 59: Technical Data

    Internet. The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label. {S/N} corresponds to the serial number of the product, see type label (if indicated).
  • Page 60: Mechanics And Electronics

    With SOPAS ET configuration software via IO-Link master (e.g. SICK SiLink2 master) • With fieldbus controller (PLC) and additional support by SICK func‐ tion blocks Serial, bidirectional point-to-point connection for signal transmission and power supply. Process data is transmitted cyclically and service data acyclically.
  • Page 61 Figure 18: RFH505, RFH510: distances required to prevent mutual interference with parallel mounting of several devices as well as from the environment 8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx...
  • Page 62: Ambient Data

    Operation: –25 °C ... +80 °C • Storage  : –25 °C ... +80 °C O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309/1KDE/2023-12-19 | SICK Subject to change without notice...
  • Page 63: Working Range Diagrams

    Dimensional drawing RFH505, RFH510, RFH515: dimensions see "Device view", page 8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 64: Accessories

    On the product page you will find accessories and, if applicable, related installation information for your product. The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label. {S/N} corresponds to the serial number of the product, see type label (if indicated).
  • Page 65: Annex

    Radio Frequency Identification RSSI Received Signal Strength Indication SOPAS ET SICK Open Portal for Application and Systems Engeneering Tool. SICK soft‐ ware for computer (Windows) for device configuration. SOPAS Device Description (Device description file, driver for SICK SOPAS ET software) Programmable Logic Controller Tag Identifier (Transponder Identification Number.
  • Page 66 SDCI Single-drop digital interface (official specification of IO-Link technology) O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309/1KDE/2023-12-19 | SICK Subject to change without notice...
  • Page 67 ANNEX 8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 68 Phone +65 6744 3732 E-Mail sales.gsg@sick.com E-Mail office@sick.com.gr E-Mail sales.gsg@sick.com Hong Kong Slovakia Phone +852 2153 6300 Phone +421 482 901 201 E-Mail ghk@sick.com.hk E-Mail mail@sick-sk.sk Detailed addresses and further locations at www.sick.com SICK AG | Waldkirch | Germany | www.sick.com...

This manual is also suitable for:

Rfh505-1004301Rfh510-1004301Rfh515-1004301

Table of Contents