SICK RFH5 Series Operating Instructions Manual

SICK RFH5 Series Operating Instructions Manual

Rfid read/write device (hf)
Hide thumbs Also See for RFH5 Series:

Advertisement

Quick Links

O P E R A T I N G I N S T R U C T I O N S
RFH5xx
RFID read/write device (HF)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RFH5 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for SICK RFH5 Series

  • Page 1 O P E R A T I N G I N S T R U C T I O N S RFH5xx RFID read/write device (HF)
  • Page 2 This work is protected by copyright. Any rights derived from the copyright shall be reserved for SICK AG. Reproduction of this document or parts of this document is only permissible within the limits of the legal determination of Copyright Law. Any modi‐...
  • Page 3: Table Of Contents

    Overview of the commissioning steps............. Operation.................... 36 Operating options..................Optical status indicators................8025309//2020-12-08 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 4 Operation via IO-Link................Maintenance..................47 Maintenance plan..................Cleaning..................... Troubleshooting................. 48 10.1 Overview of Potential Errors and Faults..........10.2 SICK service....................10.3 Repairs...................... 10.4 Returns...................... 10.5 Replacing a device with transfer of the current configuration data..Decommissioning................51 11.1 Disposal..................... Technical data..................52 12.1 Features....................
  • Page 5: About This Document

    The available device types are listed on the online product page at: • www.sick.com/RFH5xx 8025309//2020-12-08 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 6: Explanation Of Symbols

    Other publications related to the devices described here • Publications dealing with accessories O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309//2020-12-08 | SICK Subject to change without notice...
  • Page 7: Sick Service

    ABOUT THIS DOCUMENT SICK service If you require any technical information, our SICK Service will be happy to help. To find your agency, see the final page of this document. NOTE Before calling, make a note of all type label data such as type code, serial number, etc., to ensure faster processing.
  • Page 8: Safety Information

    Technical Information RFH5xx Regulatory Compliance. SICK AG assumes no liability for losses or damage arising from the use of the product, either directly or indirectly. This applies in particular to use of the product that does not conform to its intended purpose and is not described in this documentation.
  • Page 9: Improper Use

    The device must not be used in explosion-hazardous areas, in corrosive environ‐ ments or under extreme environmental conditions. • Any use of accessories not specifically approved by SICK AG is at your own risk. WARNING Danger due to improper use! Any improper use can result in dangerous situations.
  • Page 10: Requirements For Skilled Persons And Operating Personnel

    O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309//2020-12-08 | SICK Subject to change without notice...
  • Page 11: Repairs

    Repairs Repair work on the device may only be performed by qualified and authorized personnel from SICK AG. Interruptions or modifications to the device by the customer will invali‐ date any warranty claims against SICK AG. 8025309//2020-12-08 | SICK...
  • Page 12: Product Description

    Conformity symbol for Europe Part number Date of manufacture (year, calendar week) O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309//2020-12-08 | SICK Subject to change without notice...
  • Page 13 510: max. 60 mm (Short Range) 515: max. 80 mm (Short Range) 8025309//2020-12-08 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 14 Reading distance achieved depends on dimensions and quality of the transponder. Including clamping bracket O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309//2020-12-08 | SICK Subject to change without notice...
  • Page 15: Product Characteristics

    4 x LED, multi-colored (process feedback) IO-Link connection (male connector, M12, 4-pin, A-coded) 8025309//2020-12-08 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 16 4 x LED, multi-colored (process feedback) IO-Link connection (male connector, M12, 4-pin, A-coded) O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309//2020-12-08 | SICK Subject to change without notice...
  • Page 17 POWER LED, display color green Cap with integrated antenna 8025309//2020-12-08 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 18 Reading field width in mm (inch) Reading distance in mm (inch) O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309//2020-12-08 | SICK Subject to change without notice...
  • Page 19 Scope of delivery The delivery of the device includes the following components in the packaging: 8025309//2020-12-08 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx...
  • Page 20 Printed safety notes (safety The document contains safety information on han‐ information) dling the device as well as the SICK product page link for online access to the operating instructions Printed Technical Information The document includes information on: RFH5xx Regulatory Compliance •...
  • Page 21 Convenient operation • Device configuration for demonstrating the operating principle of and configuration the device in the SICK SiLink2 IO-Link master with SOPAS ET config‐ uration software • Device configuration for operational use via the system control (PLC) using an IO-Link master and the type-specific IO-Link device description file (IODD) of the RFH5xx in the configuration tool of the •...
  • Page 22 SRF55V02P 1792 Infineon SRF55V10P 7936 Fujitsu MB89R118 84/85 16000 O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309//2020-12-08 | SICK Subject to change without notice...
  • Page 23: Transport And Storage

    Avoid mechanical shocks. ■ Storage temperature: see "Technical data", page ■ 8025309//2020-12-08 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 24 For storage periods of longer than 3 months, check the general condition of all ■ components and packaging on a regular basis. O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309//2020-12-08 | SICK Subject to change without notice...
  • Page 25: Mounting

    8025309//2020-12-08 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 26 RFH515: mount the device using the supplied clamping bracket. Optional SICK brackets RFH505 or RFH510: the device can be installed using an optional SICK bracket or a customer-specific bracket. SICK offers prefabricated brackets which are optimally suited for mounting the device in a wide range of applications.
  • Page 27: Mounting Location

    MOUNTING NOTE Dimensional drawings for SICK brackets and, if applicable, mounting instructions can be found online at: www.sick.com To do so, enter the 7-digit part number of the bracket in the search field. User-supplied brackets A user-supplied bracket should meet the following requirements: Stable mounting device ■...
  • Page 28 O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309//2020-12-08 | SICK Subject to change without notice...
  • Page 29 Figure 13: Optimal alignment of the transponders for a reliable read and write process. Cap with antenna RFH515 8025309//2020-12-08 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 30 Figure 14: Optimal alignment of the transponders for a reliable read and write process. Cap with antenna O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309//2020-12-08 | SICK Subject to change without notice...
  • Page 31: Electrical Installation

    Germany, observe the following standards: DIN VDE 0100 (Part 430) and DIN VDE 0298 (Part 4) and/or DIN VDE 0891 (Part 1). 8025309//2020-12-08 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx...
  • Page 32: Wiring Instructions

    Table 6: Pin assignment of the IO-Link connection (port class type A) Signal Function + DC 24 V (supply voltage) O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309//2020-12-08 | SICK Subject to change without notice...
  • Page 33: Prerequisites

    0 V (supply voltage) C/Q1 IO-Link communication / digital output 1 Prerequisites • Use SICK IO-Link standard cables for the specified ambient temperature range, see: www.sick.com/RFH5xx ° • Do not operate the device at ambient temperatures below 0 °C when mounting or connection work is being carried out.
  • Page 34: Commissioning

    (project file) for archiving purposes. NOTE The SOPAS ET configuration software can only be used for configuration of the RFH5xx using the SICK SiLink2 or SIG200 IO-Link master. 7.1.2 Integration and commissioning of the RFH5xx in a fieldbus system using the PLC...
  • Page 35 COMMISSIONING SIG200 (IO-Link Master) Transponder Prerequisites: • IO-Link master, z. B. SICK SIG200, connected to the PLC via fieldbus • Common PLC configuration tool, if applicable function block for the RFH5xx installed • Type-specific IODDD of the RFH5xx for application in the PLC Procedure Connect the RFH5xx to the voltage-free IO-Link master via IO-Link.
  • Page 36: Operation

    The display condition for an event (yellow) dominates the display of green if the device has received a read or write command. O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309//2020-12-08 | SICK Subject to change without notice...
  • Page 37 Q2 is inac‐ tive – • IO-Link: no outstanding command 8025309//2020-12-08 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 38: Operation Via Io-Link

    Minimum cycle time 10 ms Transmission rate COM3 (230.4 kBd) O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309//2020-12-08 | SICK Subject to change without notice...
  • Page 39 To ensure that the IO-Link sensor can be easily integrated into the control program, SICK also provides function blocks for many control systems. These function blocks make it easier to read and write the individual sensor parameters, for example, and provide support when it comes to interpreting the process data supplied by the IO-Link sensor.
  • Page 40 = read only, wo = write only, rw = read/write Subindex access not supported (Power supppy voltage) O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309//2020-12-08 | SICK Subject to change without notice...
  • Page 41 IC manufacturer code: manufacturer of the transponder IC, • IC reference: specific IC type 8025309//2020-12-08 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 42 System time stamp transponder leaving reading field of device [ms] O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309//2020-12-08 | SICK Subject to change without notice...
  • Page 43 = read only, wo = write only, rw = read/write Subindex access not supported 8025309//2020-12-08 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx...
  • Page 44 2 = Alarm 1 3 = Alarm 2 4 = SIO deactivated O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309//2020-12-08 | SICK Subject to change without notice...
  • Page 45 When switching to another mode ("CMD"), the command must be started with “START” = 1 (“Process Data OUT”). 8025309//2020-12-08 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx...
  • Page 46 (4 or 8 bytes, depending on the IC used). O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309//2020-12-08 | SICK Subject to change without notice...
  • Page 47: Maintenance

    Clean using a dry towel or an industrial vacuum cleaner. Do not use cleaning agents. 8025309//2020-12-08 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx...
  • Page 48: Troubleshooting

    Tag Error No Memory Block Block Protected CRC Error O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309//2020-12-08 | SICK Subject to change without notice...
  • Page 49: Sick Service

    10.3 Repairs Repair work on the device may only be performed by qualified and authorized personnel from SICK AG. Interruptions or modifications to the device by the customer will invali‐ date any warranty claims against SICK AG. 10.4 Returns Do not dispatch devices to the SICK Service department without consultation.
  • Page 50 ID (identical type), the master automatically parameterizes the exchange device. O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309//2020-12-08 | SICK Subject to change without notice...
  • Page 51: Decommissioning

    Separate the recyclable materials by type and place them in recycling containers. ■ 8025309//2020-12-08 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 52: Technical Data

    (dimensions, quality), its position and alignment to the device and the ambient conditions. 12.2 Interfaces Table 11: Technical data for RFH5xx: Interfaces RFH505-1004301 RFH510-1004301 RFH515-1004301 IO-Link • SICK Device ID 8389190 8389191 8389192 • Part number 6072840 6072841 6072842 (device) •...
  • Page 53: Mechanics And Electronics

    Configuration • With SOPAS ET configuration software via IO-Link master (e.g. SICK SiLink2 master) • With fieldbus controller (PLC) and additional support by SICK func‐ tion blocks Serial, bidirectional point-to-point connection for signal transmission and power supply.
  • Page 54 Distance RFH505-1004301 RFH510-1004301 18 mm 30 mm O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309//2020-12-08 | SICK Subject to change without notice...
  • Page 55: Ambient Data

    0% ... 95%, non-condensing humidity Storage conditions see "Storage", page 8025309//2020-12-08 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 56: Working Range Diagrams

    Dimensional drawing RFH505, RFH510, RFH515: dimensions see "Device view", page O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309//2020-12-08 | SICK Subject to change without notice...
  • Page 57: Accessories

    Accessories and where applicable mounting information can be found online at: • www.sick.com/RFH5xx 8025309//2020-12-08 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 58: Annex

    Radio Frequency Identification RSSI Received Signal Strength Indication SOPAS ET SICK Open Portal for Application and Systems Engeneering Tool. SICK soft‐ ware for computer (Windows) for device configuration. SOPAS Device Description (Device description file, driver for SICK SOPAS ET software) Programmable Logic Controller.
  • Page 59 SDCI Single-drop digital interface (official specification of IO-Link technology) 8025309//2020-12-08 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx Subject to change without notice...
  • Page 60 E-Mail office@sick.com.gr E-Mail info@sick.ru Vietnam Hong Kong Singapore Phone +65 6744 3732 Phone +852 2153 6300 Phone +65 6744 3732 E-Mail sales.gsg@sick.com E-Mail ghk@sick.com.hk E-Mail sales.gsg@sick.com Detailed addresses and further locations at www.sick.com SICK AG | Waldkirch | Germany | www.sick.com...