6.1.1
Side installation
If the appliance is installed on the same side of the vehicle as the entrance
door, it is desirable that the door does not cover the refrigerator's vents.
If this cannot be avoided there must be a gap of at least 25mm between the door and
the vents.
Fig.1
Air vent grille blocked.
Distance between door and
vent grilles : min 25mm !
Rear installation
6.1.2
Rear installation often causes an unfavourable installation arrangement, as ideal ventila-
tion cannot always be assured (e.g. the lower ventilation grille is covered by the bumper
or the rear lights of the vehicle!) (Fig. 2). The maximum cooling performance of the aggre-
gate is actually not available.
Another variant of the rear installation is the side installation of the ventilation grilles . The
air-heat recirculation is very restricted which means the heat exchangers (condenser,
absorber) cannot be adequately cooled. The variant with an additional ventilation grille
mounted in the floor also has a bad airflow duct.
The maximum cooling performance is not available!
Please assure at all the installation variations correct ventilation and extrac-
tion, as described in item 6.3!
An installation that is not carried out by qualified persons causes a
reduction in the cooling capacity and will jeopardize the manufactur-
er's guarantee.