Recommended Connectivity Chart; Hardware Designs - Ebyte E42-400M20S User Manual

Hw3000 400mhz 100mw spi wireless module
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.
13
GPIO0
14
IRQ
15
PDN
16
MISO
17
MOSI
18
SCK
19
CSN
20
GND
21
ANT
22
GND

4. Recommended Connectivity Chart

5. Hardware Designs

It is recommended to use a DC regulated power supply to power this module, the power supply ripple factor is as
small as possible, and the module needs to be reliably grounded;
Please pay attention to the correct connection of the positive and negative terminals of the power supply, such as
reverse connection may cause permanent damage to the module;
Please check the power supply to ensure that it is between the recommended supply voltages, if it exceeds the
maximum value it may cause permanent damage to the module;
please check the power supply stability, the voltage should not fluctuate significantly and frequently;
Copyright ©2012–2024,Chengdu Ebyte Electronic Technology Co.,Ltd.
General-purpose digital I/O (see HW3000 chip manual for function
Input/Output
details)
Outputs
Interrupt output pin (polarity assignable, default active low)
Inputs
POWER DOWN mode enable input pin (active high)
Outputs
SPI Data Output Pin
Inputs
SPI Data Input Pin
Input
SPI clock input pin
Input
SPI chip select signal (active low)
GND
Ground, connect to power reference ground
Antenna connector, stamp hole (50 ohm characteristic impedance)
GND
Ground, Connect to Power Reference Ground