Indication Of Failures And Error Resolution; The Red Led „Voltage <25.4V; The Red Led „Error", Battery Defective (Permanent Light); The Red Led „Error", Battery Defective (Led Flashing) - Nortec EL11 Operating Instructions Manual

Charger/trickle-charger
Table of Contents

Advertisement

19-Dec-23
28,8 V
28,6 V
25,4 V
5/10 A
1 A
I-c harge
Picture 8:
Charging curve of partly-discharged battery

2.5 Indication of failures and error resolution

2.5.1 The red LED „VOLTAGE <25.4V"
The error indication is illuminated if the battery voltage decreases below 25.4V. This characterizes the
edge of starting ability of the vehicle by all means. This error indication might shine together with the
yellow LEDs "LADUNG" = CHARGE or "ERHALTUNGSLADUNG" = TRICKLE-CHARGE (permanent
light).
2.5.2 The red LED „error", battery defective (permanent light)
The permanent light is illuminated if the charging cable is not correctly connected or a battery failure
emerged.
2.5.3 The red LED „error", battery defective (LED flashing)

3. SAFETY INSTRUCTIONS

While charging the safety note for users (Picture 9) has to be positioned inside the vehicle in the focus
of the driver.

3.1 Safety note for users

During the charge with EL11 normally the mains switch of the tank is switched off. In the cover of this
manual you will find the warning sign for the tank driver.
© Nortec Electronics 2023
U -c harge