Download Print this page

Toshiba TC90101FG Manual page 28

Advertisement

 
 
BUS address 
2BH:D1-D0  An integral coefficient 
of Peak AGC detection 
2CH:D7 
Sync AGC 
2CH:D3-D2  Sync AGC attack time 
2CH:D1-D0  Peak/Sync AGC recovery  
time 
2DH:D7 
LPF for CCD 
2DH:D6 
CCD slice function mode  It set mode of CCD slice function. 
2DH:D5 
CCD slice level 
2DH:D3 
Phase width of ID1  
detection 
2DH:D2 
CCD Start bit detection  It is the detection sensitivity of the start bit of CCD. 
2DH:D1-D0  Select CCD field 
2EH:D7 
LPF for ID1 
2EH:D6 
ID1 data slice function  It set ID1 data slice function.  
2EH:D5-D4  ID1 slice level 
2EH:D3 
Detection for amplitude 
of ID1 signal 
2EH:D2 
Phase of ID1 detection  It is the reference phase of the ID1 detection. 
2EH:D1-D0  Sampling phase of ID1 
2FH:D7 
LPF for WSS1 
2FH:D6 
WSS data slice function  It set WSS data slice function.  
2FH:D5-D4  WSS slice level 
2FH:D2 
WSS SC Det mode 
2FH:D1-D0  Select WSS field 
30H:D7-D4  Adjust  line  timing  of  CCD 
 
30H:D3-D0  Adjust  line  timing  of  ID1 
 
31H:D7-D4  Adjust  line  timing  of  WSS 
 
31H:D3 
fsc pull in 
31H:D2 
13.5MHz trap  
31H:D1 
IIR Filter selection 
31H:D0 
IIR Filter ON/OFF 
Feb./2005 
Function 
It is the integral-coefficient of Peak AGC detection. 
 
It set ON/OFF of Sync AGC. 
It set Sync AGC attack time.  
It set recovery time of Peak AGC and Sync AGC. 
It set ON/OFF of LPF for CCD. 
Level changes by the input amplitude,when Auto mode. 
It set CCD slice level. 
It is effective when 2DH:D6 is set a fix. 
It set phase width of ID1 detection. 
It set field that detect CCD. 
It set ON/OFF of LPF(Input stage of ID1-detection circuit) 
When Auto slice,slice level changes by the input amplitude.
It set ID1 slice level. 
It is effective when 2EH:D6. 
It is the reference amplitude of the detection. 
When it is off, Amplitude detection becomes AUTO.  
When Adaptive , it can search in the range of ±1.1μs 
at the D1. 
It is the phase of the detection of ID1.  
"1" changes in 0.12µs unit at D1, 0.28µs unit at D2. 
It usually uses on "0". 
It set ON/OFF of LPF(Input stage of WSS-detection circuit) 
When Adaptive slice,slice level changes by the input 
amplitude. 
It set WSS slice level. 
It is effective when 2FH:D6. 
It set detection sensitivity of start-code of WSS. 
It set field that detect WSS. 
It is Delay-adjust of LINE-timing for the CCD detection.  
It uses when detection start deviates in weak electric density
It is Delay-adjust of LINE-timing for the ID1 detection.  
It uses when detection start deviates in weak electric density
It is Delay-adjust of LINE-timing for the WSS detection.  
It uses when detection start deviates in weak electric density
It set sensitivity of Pulled-in of fsc. 
High: Sensitivity is up. 
It set ON/OFF of 13.5MHz Trap at ADC. 
It usually uses on "ON". 
Characteristic selecting of C-filter of SECAM.  
It set ON/OFF of C-filter of SECAM. 
A color beat can be reduced. 
It usually uses on "Always ON" in SECAM. 
 
Contents 
 
TC90101FG  
28 