BUS address
24H:D2
AFC leak control
24H:D1-D0 The order of read Data
25H:D7
Data insert of H
25H:D6
Data insert of V
25H:D5
Data insert for 601
25H:D4-D0 Line number for insert
Data.
26H:D7-D4 Line number for insert
Data in field blank.
26H:D3-D0 For DID code
27H:D7-D0 For DID code
28H:D7-6
Histerisis for color
stripe detection
28H:D5-D4 Histerisis for color
stripe detection
28H:D3-D2 Mask period for color
stripe detection
28H:D1-D0 Sensitivity for color
stripe detection
29H:D7
Color stripe detection It set ON/OFF of color stripe detection.
29H:D5
AGC detection periode
29H:D4
Pulse width of Pseudo
sync
29H:D2
Pseudo H sync detection It set ON/OFF of pseudo H sync detection.
29H:D1-D0 Slice level for pseudo H
sync
2AH:D7
LPF for AGC pulse &
pseudo H sync detection
2AH:D6
Route change of AGC pulse
& pseudo H sync
2AH:D4
AGC Pulse detection
2AH:D3-D2 Slice level for AGC pulse It set slice level of AGC pulse.
2AH:D1-D0 Histerisis time for AGC
pulse detection
2BH:D7
Peak AGC ON/OFF
2BH:D6-D5 Limit level of Peak AGC It set Limit level of Peak AGC.
2BH:D4
fsc Trap Filter
2BH:D3-D2 Peak AGC attack time
Feb./2005
Function
It is Leak-control in the AFC circuit.
It usually uses on OFF.
It can change order that Read-data.
00: ABCD
A:Detection、B:CCD、C:ID1、D:WSS
BUS:01=BCAD、BUS:10=CABD、BUS:11=DABC
It insert Read-data to the H period of the output.
Data is inserted after EAV at 656.
Data is inserted same place with 656 at 601.
It insert Read-data to the V period of the output.
Data is inserted after EAV at 656.
Data is inserted same place with 656 at 601.
Data can insert on either of Y or CbCr at 601 output.
Data cannot insert both line.
Set line which Read-Data insert.
It can set each 1-line for 1bit.
Set line(in Field-Blanking) which Read-Data insert.
It can set each 1-line for 1bit.
This setup is DID code.
This setup is DID code.
It is Histerisis of the Color-stripe-detection.
If takes the long time, detection-time increase.
But, miss-detection decreases.
It is Histerisis of the Color stripe detection-OFF.
If takes the long time, detection-OFF-time increase.
But, miss-detection decreases.
It is the detection period of color-stripe.
It is judged in more than the setup period.
It is the detection sensitivity of color-stripe.
It is judged in more than the setup.
It is the Pulse width of the AGC detection.
It is the Pulse width of the pseudo-sync pulse.
It set slice level of pseudo H sync.
It set ON/OFF of LPF for AGC pulse & pseudo H sync detection
It is Route of "AGC pulse & pseudo H sync".
Switching of Route is before and after the AGC circuit.
It set ON/OFF of AGC Pulse detection.
It set histerisis-time of AGC pulse detection.
It set ON/OFF of peak AGC.
It set ON/OFF of fsc Trap Filter.
It set Peak AGC attack time.
Contents
TC90101FG
27