Velocity PHTM2136CB Installation, Operating And Service Instructions

Velocity PHTM2136CB Installation, Operating And Service Instructions

Advertisement

Quick Links

Installation, Operating and Service Instructions for
Models:
• PHTM2136C
• PHTM2136CB
• PHTM2200C
Manual Contents
1.
Installer Read Before Proceeding . . . . . . . . . . .3
2.
3.
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . .5
4.
How It Works . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
5.
Locating Boiler . . . . . . . . . . . . . . . . . . . . . . . . .10
6.
Preparing Boiler . . . . . . . . . . . . . . . . . . . . . . . .14
7.
General Venting . . . . . . . . . . . . . . . . . . . . . . . . .17
8.
Sidewall Direct Venting . . . . . . . . . . . . . . . . . . .24
9. Vertical Direct Venting . . . . . . . . . . . . . . . . . . .30
10. Heating System Piping . . . . . . . . . . . . . . . . . . .36
11. Domestic Water Piping . . . . . . . . . . . . . . . . . . .39
12. Gas Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
13. Field Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
14. Condensate Disposal . . . . . . . . . . . . . . . . . . . .47
15. Start-Up and Checkout . . . . . . . . . . . . . . . . . .48
16. Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55
17. Before Leaving Jobsite . . . . . . . . . . . . . . . . . .67
18. Service and Maintenance . . . . . . . . . . . . . . . . .68
19. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . .73
20. Internal Wiring Diagrams . . . . . . . . . . . . . . . . .91
21. Service Parts . . . . . . . . . . . . . . . . . . . . . . . . . . .94
22. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .100
Appendix
D. Code Required Text . . . . . . . . . . . . . . . . . . . . .105
This boiler must only be installed, serviced, or repaired by a qualified heating installer or service technician.
Improper installation, adjustment, alteration, service or maintenance can cause severe personal injury, death,
or substantial property damage. For assistance or additional information, consult a qualified installer, service
agency, or the gas supplier. Read these instructions carefully before installing.
110331-07 - 8/23
II
• Combi Boiler/Water Heater
• Condensing
• Direct Vent
• Gas Fired
TO THE INSTALLER:
Affix these instructions adjacent to boiler.
Provide model number and serial number when
Page
seeking information and support.
TO THE HOMEOWNER:
Retain these instructions for future reference.
Contact heating installer or technician for all issues
and support.
!
WARNING

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PHTM2136CB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Velocity PHTM2136CB

  • Page 1: Table Of Contents

    Installation, Operating and Service Instructions for • Combi Boiler/Water Heater • Condensing • Direct Vent • Gas Fired Models: • PHTM2136C • PHTM2136CB • PHTM2200C TO THE INSTALLER: Affix these instructions adjacent to boiler. Provide model number and serial number when Manual Contents Page seeking information and support.
  • Page 2 Combi Installation, Operating & Service Instructions PHTM II The Massachusetts Board of Plumbers and Gas Fitters has listed the PHTM II Boiler. See the Massachusetts Board of Plumbers and Gas Fitters website for the latest Approval Code or ask your local Sales Representative. The Commonwealth of Massachusetts requires this product to be installed by a licensed Plumber or Gas fitter.
  • Page 3: Installer Read Before Proceeding

    Combi Installation, Operating & Service Instructions PHTM II Installer or Qualified Service Agency Read Before Proceeding NOTICE: Size boiler properly relative to design WARNING heat load or, if using DHW priority, the peak Asphyxiation Hazard, Burn Hazard, Electrical hot water load, whichever is larger. A grossly Shock Hazard.
  • Page 4: Homeowner Read Before Proceeding

    Combi Installation, Operating & Service Instructions PHTM II User/Homeowner Read Before Proceeding DANGER WARNING Asphyxiation Hazard. Fire Hazard. • A qualified installer, service agency or gas supplier should annually inspect boiler including annually inspecting all vent gaskets and replacing any exhibiting damage or deterioration.
  • Page 5: Specifications

    95.0 13.6 3.7 (14) 3.4 (13) 2.9 (11) 0.5 (2) PHTM2136CB PHTM2200C 95.0 5.2 (19.6) 4.7 (17.8) 4.0 (15) 0.5 (2) DHW ratings are not AHRI certified. Input and DHW draw limits for elevations up to 2,000 ft. (610 m) with min vent length. See Table 3-3 and 3-4 for derate at max vent length and altitude.
  • Page 6 Model Number Intake/Vent Size in. (mm) ft. (m) ft. (m) Max. Length (%) Standard 2 (60) 2.5 (0.76) 70 (21.3) PHTM2136C PHTM2136CB w/ increaser 3 (80) 2.5 (0.76) 135 (41.1) Standard 2 (60) 2.5 (0.76) 70 (21.3)* PHTM2200C w/ increaser 3 (80) 2.5 (0.76)
  • Page 7 Combi Installation, Operating & Service Instructions PHTM II Specifications (continued) Vent Safety Connector Relief Air Intake Valve Front View 120 VAC Low Voltage Knockouts Knockouts Domestic Cold Water Boiler Inlet Supply Boiler Return Combi Block Drain (hydronic side) Domestic Condensate Trap Hot Water Cleanout Outlet...
  • Page 8: How It Works

    Combi Installation, Operating & Service Instructions PHTM II 12. Boiler supply temperature sensor (UL 353 How It Works Listed) Dual element temperature sensor used to monitor 1. Heat exchanger boiler water exiting heat exchanger. Boiler control Water flows through heat exchanger's stainless uses supply temperature to initiate CH burner steel tubes.
  • Page 9 Combi Installation, Operating & Service Instructions PHTM II How It Works (continued) Figure 4-1: How It Works 110331-07 - 8/23...
  • Page 10: Locating Boiler

    Combi Installation, Operating & Service Instructions PHTM II Locating Boiler 4. Locate boiler to avoid water damage in case there is a leak. If boiler must be located in an Code Requirements area sensitive to water damage, install drain WARNING pan underneath boiler and pipe to a suitable drain location.
  • Page 11 Combi Installation, Operating & Service Instructions PHTM II Locating Boiler (continued) Ventilation Air 3. If 24 in. clearances described in (2) cannot be maintained, provide two openings into room, one 1. Combustion air must be obtained directly near floor and other near ceiling. Top of upper from outdoors, however ventilation openings opening to be within 12 in.
  • Page 12 Combi Installation, Operating & Service Instructions PHTM II Locating Boiler (continued) 4. If boiler is installed in room with other appliances, Table 5-2: Corrosive Combustion Air provide adequate air for combustion and/or Contaminants and Sources ventilation in accordance with other appliance Contaminants to avoid: manufacturer's instructions and applicable code.
  • Page 13 Combi Installation, Operating & Service Instructions PHTM II Locating Boiler (continued) Connecting New Boiler to Existing Vent 1. Seal any unused openings in the common venting System system. 2. Visually inspect the venting system for proper size WARNING and horizontal pitch and determine there is no Asphyxiation Hazard.
  • Page 14: Preparing Boiler

    Combi Installation, Operating & Service Instructions PHTM II Preparing Boiler Unpack Boiler CAUTION Remove boiler and miscellaneous parts carton from Heavy Object. outer shipping carton. Boiler weighs up to 130 lb (59 kg). Two people are required to lift boiler onto wall mounting CAUTION bracket.
  • Page 15 Combi Installation, Operating & Service Instructions PHTM II Preparing Boiler (continued) Install Vent Connector Preparing for Fuel Conversion If using LP gas. LP conversion requires (2) 1. Remove vent connector and screws from steps: gas valve setting adjustment and control miscellaneous parts carton.
  • Page 16 Combi Installation, Operating & Service Instructions PHTM II Preparing Boiler (continued) 3. For wood studs, drill 3/16 in. (4.8 mm) pilot holes Mount Boiler "A" and "B" and attach bracket using provided 1. Wall bracket is designed to mount on studs with 5/16 in.
  • Page 17: General Venting

    Combi Installation, Operating & Service Instructions PHTM II General Venting Direct Vent Sidewall Termination Options Figure 7-2: Sidewall Low Figure 7-3: Sidewall Figure 7-1: Sidewall Profile Termination - see Concentric Termination - Termination with Fittings - Section 8 for details see Section 8 for details see Section 8 for details Direct Vent Vertical Termination Options...
  • Page 18 Combi Installation, Operating & Service Instructions PHTM II General Venting (continued) 1. Min and max lengths are calculated separately for air and vent. For example, max length 135 ft. (41.1 Vent and Air Sizing m) means up to 135 ft. (41.1 m) air piping and up to 135 ft.
  • Page 19 Combi Installation, Operating & Service Instructions PHTM II General Venting (continued) 5. Example equivalent length calculation for 2 in. NOTICE: PVC may not be used to penetrate vent: combustible or non-combustible walls unless all A. 1 ft. CPVC straight pipe =1 eq ft. of the following conditions are met.
  • Page 20 Combi Installation, Operating & Service Instructions PHTM II General Venting (continued) use #10 x 1 in. sheet metal screw to secure. Seal 6. CPVC/PVC vent starter kits are available. Kits joint between air connector and pipe with RTV include 30 in. (760 mm) CPVC pipe, 90° short silicone.
  • Page 21 Combi Installation, Operating & Service Instructions PHTM II General Venting (continued) Maximum Wall 2"* 6" 12" Thickness ("T") (50mm) (150mm) (305mm) Minimum air space 0"* 1" 1-3/4" around pipe ("C") (0mm) (25mm) (45mm) One end of opening may *Wall must be of non-combustible construction be closed PVC Vent Pipe 66"...
  • Page 22 Combi Installation, Operating & Service Instructions PHTM II General Venting (continued) Polypropylene Venting Table 7-16: Listed Polypropylene Vent Materials (ULC-S636 Listed) WARNING Manufacturer Model Asphyxiation Hazard. • Use only vent materials listed in Table 7-16 Polypropylene Single Wall Rigid DuraVent to make vent connections.
  • Page 23 Combi Installation, Operating & Service Instructions PHTM II General Venting (continued) Table 7-17: Listed Polypropylene Vent Fittings Length DuraVent PolyPro Centrotherm InnoFlue Selkirk PolyFlue 2 in. (60 mm) 2PPS-LC IANS02 PF-LB Joint Connector 3 in. (80 mm) 3PPS-LC IANS03 PF-LB or 4PF-LB 2 in.
  • Page 24: Sidewall Direct Venting

    Combi Installation, Operating & Service Instructions PHTM II Sidewall Direct Venting Determine Terminal Location C. Minimum 12 in. (305 mm) from inside corner. 6 ft. (1.8 m) is generally recommended and WARNING required when window and/or air inlet is within Asphyxiation Hazard.
  • Page 25 Combi Installation, Operating & Service Instructions PHTM II Sidewall Direct Venting (continued) 110331-07 - 8/23...
  • Page 26 Combi Installation, Operating & Service Instructions PHTM II Sidewall Direct Venting (continued) Table 8-3: Polypropylene Sidewall Terminal Fittings CPVC/PVC or Polypropylene Fittings DuraVent Centrotherm Terminal Selkirk PolyFlue PolyPro InnoFlue WARNING UV resistant UV stabilized UV resistant Asphyxiation Hazard. single wall pipe end pipe + two pipe + two 2PF- All CPVC/PVC vent joints must be glued.
  • Page 27 Combi Installation, Operating & Service Instructions PHTM II Sidewall Direct Venting (continued) 1. Low profile terminals listed in Table 8-7 may be DuraVent & Selkirk: Remove gasket to used to terminate air and vent outside building install screen per Figure 8-8. Both air and vent pipes must From boiler Elbow vent connection...
  • Page 28 Combi Installation, Operating & Service Instructions PHTM II Sidewall Direct Venting (continued) CPVC/PVC Concentric Terminal 3. Follow terminal manufacturer's instructions and Figure 8-11 for assembly. WARNING 4. If needed, terminal can be shortened. Follow Asphyxiation Hazard. terminal manufacturer's instructions and Figure All CPVC/PVC vent joints must be glued.
  • Page 29 Combi Installation, Operating & Service Instructions PHTM II Sidewall Direct Venting (continued) Kit Size *'A' Manufacturer 7-3/8" (187mm) 1-3/4" (44mm) *Overall length of inner IPEX 3-1/2" (89mm) 2" pipe to be 'A' longer than overall 12-3/16" (310mm) 3/4" (19mm) DIVERSITECH length of outer pipe.
  • Page 30: Vertical Direct Venting

    Combi Installation, Operating & Service Instructions PHTM II Vertical Direct Venting Determine Terminal Location WARNING WARNING Asphyxiation Hazard. Asphyxiation Hazard. All polypropylene vent systems rely on gaskets Follow these instructions when determining vent for sealing. Ensure gaskets are installed in terminal location.
  • Page 31 Combi Installation, Operating & Service Instructions PHTM II Vertical Direct Venting (continued) Table 9-2: Polypropylene Vertical Terminal Fittings DuraVent & Selkirk: Elbow Remove gasket to DuraVent Centrotherm install screen Joint Selkirk PolyFlue PolyPro InnoFlue Connector Screen UV resistant UV stabilized UV resistant single wall pipe end pipe +...
  • Page 32 Combi Installation, Operating & Service Instructions PHTM II Vertical Direct Venting WARNING (continued) Asphyxiation Hazard. CPVC/PVC Concentric Terminal If using stainless steel screw to attach rain cap, always drill clearance hole in rain cap WARNING and pilot hole in vent pipe appropriate for Asphyxiation Hazard.
  • Page 33 Combi Installation, Operating & Service Instructions PHTM II Vertical Direct Venting (continued) Abandoned B-vent Chase Polypropylene Concentric Terminal WARNING WARNING Asphyxiation Hazard. • Only abandoned (unused) B-vent may Asphyxiation Hazard. be used as a chase. Failure to comply All polypropylene vent systems rely on gaskets may cause product damage or improper for sealing.
  • Page 34 Combi Installation, Operating & Service Instructions PHTM II Vertical Direct Venting (continued) Centrotherm Innoflue IFBK02 or IFBK03 (3.1m) B-Vent Kit Table 9-11: Polypropylene B-vent Chase B-Vent 24" (610mm) Components Flashing 12" (305mm) DuraVent Centrotherm Normal snow Selkirk PolyFlue line on roof PolyPro InnoFlue 2PF-10UV or...
  • Page 35 Combi Installation, Operating & Service Instructions PHTM II Vertical Direct Venting Vent (continued) Note: Duravent Polypro Flex Abandoned Chimney Chase components shown. WARNING Asphyxiation Hazard. PPs Flex Only abandoned (unused) masonry chimney may be used as a chase. If chimney contains Clean, tight unused chimney multiple flues, all flues must be abandoned.
  • Page 36: Heating System Piping

    Combi Installation, Operating & Service Instructions PHTM II Heating System Piping If replaced, replacement must have a setting General System Piping Precautions less than or equal to maximum allowable WARNING working pressure (MAWP) shown on ASME data plate located on left side of heat Asphyxiation Hazard.
  • Page 37 Combi Installation, Operating & Service Instructions PHTM II Heating System Piping (continued) 5. Automatic air vent (required) B. This is a water tube boiler and this flow switch A. Factory installed manual air vent is included is therefore only effective way to provide on boiler heat exchanger, to vent heat such protection.
  • Page 38 Combi Installation, Operating & Service Instructions PHTM II Heating System Piping (continued) 110331-07 - 8/23...
  • Page 39: Domestic Water Piping

    Combi Installation, Operating & Service Instructions PHTM II Domestic Water Piping NOTICE: Elbows pointed toward back of boiler DANGER are recommended to start DHW piping. Scald Hazard. • Under certain conditions this boiler DHW components in this system and their functions are can deliver domestic hot water (DHW) at as follows: temperatures in excess of DHW set point on...
  • Page 40 Combi Installation, Operating & Service Instructions PHTM II Domestic Water Piping (continued) 110331-07 - 8/23...
  • Page 41 Combi Installation, Operating & Service Instructions PHTM II Domestic Water Piping (continued) 110331-07 - 8/23...
  • Page 42: Gas Piping

    Combi Installation, Operating & Service Instructions PHTM II Gas Piping WARNING DANGER Explosion Hazard. Explosion Hazard. • Failure to properly pipe gas supply to boiler Do not use matches, candles, open flames or could cause improper operation or leaks of other ignition sources to check for leaks.
  • Page 43: Field Wiring

    Combi Installation, Operating & Service Instructions PHTM II Field Wiring Locating Field Connection Terminal Strips DANGER Field connection terminal strip locations are shown in Electrical Shock Hazard. Figure 13-1. To access terminal strips: • Disconnect electrical supply before installing or performing maintenance. 1.
  • Page 44 Combi Installation, Operating & Service Instructions PHTM II Field Wiring (continued) Low Voltage Connections 1. All low voltage field connections to boiler are made on Low Voltage Connections terminal strip (see Figure 13-3) located on left side of bottom panel. Route all low voltage wiring through conduit knock out holes located on left side in 120V Boiler...
  • Page 45 Combi Installation, Operating & Service Instructions PHTM II Field Wiring (continued) 2. External power must not be applied to any low E. Recirculation (Header) Temperature voltage terminals - doing so may damage boiler Sensor - When optional sensor is control. Note following: installed and Recirculation (Comfort) Mode is enabled, boiler will attempt to A.
  • Page 46 Combi Installation, Operating & Service Instructions PHTM II Field Wiring (continued) Figure 13-5: TACO SR504 or Equivalent Zone Panel Wiring Connection Diagram 110331-07 - 8/23...
  • Page 47: Condensate Disposal

    Combi Installation, Operating & Service Instructions PHTM II Condensate Disposal B. Do not route or terminate condensate drain WARNING line piping through an area that is prone Asphyxiation Hazard. to freezing temperatures or that could Failure to install condensate drain in be damaged by leaking condensate.
  • Page 48: Start-Up And Checkout

    Combi Installation, Operating & Service Instructions PHTM II Start-Up and Checkout Heating System Cleaning and Treatment Fill Water Quality CAUTION NOTICE: Make sure system is filled with water Component Damage. meeting the following criteria: Proper flushing, cleaning, and water side •...
  • Page 49 Combi Installation, Operating & Service Instructions PHTM II Start-Up and Checkout Final Check Before Starting Boiler (continued) 4. Eliminate air in boiler by bleeding from heat WARNING exchanger manual air vent on top left side of heat Asphyxiation Hazard. Burn Hazard. exchanger (Figure 15-1).
  • Page 50 Combi Installation, Operating & Service Instructions PHTM II Start-Up and Checkout (continued) 3. Use keypad to enter adjust mode and change LP Conversion parameter A06 from "0" to "1". WARNING Press and hold "menu" for 3 seconds. • Asphyxiation Hazard. Press ""...
  • Page 51 Combi Installation, Operating & Service Instructions PHTM II Start-Up and Checkout (continued) Final Check Before Starting Boiler 4. If boiler does not light after 2 retries for ignition, it will enter a "soft lockout" and will wait for one hour (continued) before attempting another ignition sequence.
  • Page 52 Combi Installation, Operating & Service Instructions PHTM II Start-Up and Checkout (continued) 10. Perform combustion test. 9. Check inlet gas pressure (Figure 15-9). Verify inlet gas pressure is between upper and lower limits WARNING shown on rating label with all gas appliances on Asphyxiation Hazard.
  • Page 53 Combi Installation, Operating & Service Instructions PHTM II Start-Up and Checkout (continued) FOR YOUR SAFETY READ BEFORE OPERATING/POUR VOTRE × × × × SECURITE LISEZ AVANT DE METTRE EN MARCHE WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 54 Combi Installation, Operating & Service Instructions PHTM II Start-Up and Checkout (continued) Boiler Sequence of Operation Table 15-11: Boiler Sequence of Operation Status Screen Display Description Burner - Off Pump(s) - Off Three Way Valve - DHW Priority: Standby There is no call for heat, boiler is not firing and priority is "standby". Boiler is ready to Status: respond to a call for heat.
  • Page 55: Operation

    Combi Installation, Operating & Service Instructions PHTM II Operation User Display Overview reset – Figure 16-1: Display Icons Table 16-2: Display Descriptions When not flashing or alternating display temperature is: 120°F • DHW outlet temperature during DHW priority. • Boiler supply temperature at all other times. Visible when Central Heat demand is present.
  • Page 56 Combi Installation, Operating & Service Instructions PHTM II Operation (continued) Operating Mode The STA (status) display code contains below listed Basic boiler status is displayed and DHW setpoint values. may be adjusted. Table 16-5 Managing of Status Numbers Description (see Section 19 reset Display Troubleshooting for explanation)
  • Page 57 Combi Installation, Operating & Service Instructions PHTM II Operation (continued) Adjust Mode Menu Diagnostic information and Quick Menu parameters are available without entering a password. Press and Hold “menu” button for 3 seconds to access Adjust Mode. reset Press Press buttons buttons to view next to adjust...
  • Page 58 Combi Installation, Operating & Service Instructions PHTM II Operation (continued) Accessing Password Protected Menus Password protected parameters are available by entering a password. Press and hold the "menu" for 3 seconds, reset Press "" or "" buttons until PAS is visible and press "enter". Press "enter"...
  • Page 59 Combi Installation, Operating & Service Instructions PHTM II Operation (continued) Table 16-11: Menu A A , Quick Menu (items A06, A07, A08 and A09 visible only after password entered) Range/ Default Parameter and Description Choices A01 Boiler On/Off Switch On/Off Boiler switch allows an installer to prevent boiler starts while boiler powered and reviewing boiler settings.
  • Page 60 Combi Installation, Operating & Service Instructions PHTM II Operation (continued) Table 16-12: Menu FR FR, Firing Rate (visible only after password entered) Range/ Default Parameter and Description Choices F01 Manual Modulation Enable Setting to "On" allows technician to fire at rate specified in F02. To return to Auto change setting to "Off".
  • Page 61 Combi Installation, Operating & Service Instructions PHTM II Operation (continued) Table 16-13: Menu 5P 5P, , Setpoint Menu (visible only after password entered) Range/ Default Parameter and Description Choices 501 Temperature Units Sets display temperature in degrees Fahrenheit or Celsius. 0, 1 Fahrenheit Celsius...
  • Page 62 Combi Installation, Operating & Service Instructions PHTM II Operation (continued) Table 16-15: Menu PU PU, Pump Menu (visible only after password entered) Range/ Default Parameter and Description Choices P01 System Pump Output Select: Activates System Pump output according to selected function. System Pump Any Pump Runs during any call for heat.
  • Page 63 Combi Installation, Operating & Service Instructions PHTM II Operation (continued) Table 16-16: Menu LL LL, Lead Lag Menu (visible only after password entered) Range/ Default Parameter and Description Choices L01 Lead Lag Master Enable [Not for Combi boilers] Used to "turn on" Multiple Boiler Controller On/Off Sequencer Master is Enabled.
  • Page 64 Combi Installation, Operating & Service Instructions PHTM II Operation (continued) This section covers control features available via local display. For additional control features available via our App, see Extended Features Manual available on our website or in our App. 6. Sensorless Reset Control System Overview Control system monitors recent firing rate and The control manages all of the following boiler...
  • Page 65 Combi Installation, Operating & Service Instructions PHTM II Operation (continued) 12. Priority Demand 2. High Differential Temperature Limit Control accepts a call for heat from multiple Control monitors temperature difference between places and responds to its "Priority". When more return and supply sensors. If this difference than one demand is present, higher priority exceeds 58°F (32°C) control begins to reduce demand is used to determine active boiler...
  • Page 66 Combi Installation, Operating & Service Instructions PHTM II Operation (continued) Boiler Protection Features (continued) Table 16-19: Frost Protection Interlocks 7. Flue High Limit Device Start Temperatures Stop Temperatures Control monitors flue temperature sensor located Started at top of heat exchanger. If flue temperature Outdoor Air Outdoor Air exceeds 194°F (90°C), control begins to reduce...
  • Page 67: Before Leaving Jobsite

    Combi Installation, Operating & Service Instructions PHTM II Before Leaving Jobsite Before leaving jobsite Installed ASSE 1017 or 1070 tempering valve  Installed wall retaining clips (bottom)  Flushed heating system  Boiler and system filled with water  Air purged from boiler system ...
  • Page 68: Service And Maintenance

    Combi Installation, Operating & Service Instructions PHTM II Service and Maintenance Important Product Safety Information: Refractory Ceramic Fiber Product WARNING Some boiler components use materials that contain refractory ceramic fibers (RCF). RCF has been classified as a possible human carcinogen. When exposed to elevated temperatures, RCF may change into crystalline silica, a known carcinogen.
  • Page 69 Combi Installation, Operating & Service Instructions PHTM II Service and Maintenance (continued) Monthly Inspections: WARNING 1. Inspect vent piping and air intake piping to Asphyxiation Hazard. Fire Hazard. Explosion verify it is free from leakage and deterioration. Hazard. Also verify vent and air intake terminals are •...
  • Page 70 Combi Installation, Operating & Service Instructions PHTM II Service and Maintenance (continued) 7. Inspect ignitor/flame sensor. A. Clean off any deposits found with steel wool. Do not use sand paper or Emory cloth for this cleaning. B. Inspect ceramic portion for cracks and replace ignitor/flame sensor if any are found.
  • Page 71 Combi Installation, Operating & Service Instructions PHTM II Service and Maintenance (continued) 9. Inspect and clean condensate trap. NOTICE: Attempting to clean heat exchanger or trap with anything other than water or vinegar A. Place bucket under condensate clean out could damage heat exchanger or result in cap on bottom of boiler (Figure 18-5) to catch condensate backup, causing boiler to shut down.
  • Page 72 Combi Installation, Operating & Service Instructions PHTM II Service and Maintenance (continued) E. Refer to Sections 7 thru 9 to re-assemble 15. Place boiler back into operation. any vent system components that are A. Replace any wiring which has been disassembled during this inspection and for disconnected.
  • Page 73: Troubleshooting

    Combi Installation, Operating & Service Instructions PHTM II Troubleshooting WARNING Electrical Shock Hazard. Turn off power to boiler before working on wiring. A. Troubleshooting with No Active Fault Code Displayed Table 19-1: Troubleshooting with No Active Fault Code Indication Possible Causes Corrective Action Display Completely Check breaker and wiring between breaker panel and...
  • Page 74 Combi Installation, Operating & Service Instructions PHTM II Troubleshooting (continued) Table 19-1: Troubleshooting with No Active Fault Code (continued) Indication Possible Causes Corrective Action Draw rate exceeds combi's rated Verify draw rate and temperature rise are both at capacity. or below ratings shown in Table 3-1. Draw rate below combi's rated Verify draw rate is above rating shown in Table capacity.
  • Page 75 Combi Installation, Operating & Service Instructions PHTM II Troubleshooting (continued) In the event of high CO (CO air free greater than 200 ppm for 0-2,000 ft. (0-610 m) or greater than 300 ppm for above 2,000 ft. (610 m)) follow below steps in specified order: 1.
  • Page 76 Combi Installation, Operating & Service Instructions PHTM II Troubleshooting (continued) B. Troubleshooting with Status Numbers In Operating Mode, use arrow keys ("" or "") to reach "StA". Display will then alternate between "StA" and number shown below. Table 19-2: Status Number Explanation Display Description Explanation...
  • Page 77 Combi Installation, Operating & Service Instructions PHTM II Troubleshooting (continued) C. Troubleshooting with Diagnostic Codes In Diagnostic and Quick Menu Mode, use the arrow keys ("" or "") to reach "c" menu and press "enter" button to view diagnostic codes. Table 19-3: Diagnostic Menu Display Name...
  • Page 78 Combi Installation, Operating & Service Instructions PHTM II Troubleshooting (continued) D. Troubleshooting with Active Fault Code. Control uses following codes to describe abnormal operation: Table 19-4: Lockout/Hold/Warning Symbol Description Code Type Boiler Status Description When a lockout occurs, boiler will shut down and event is stored in history, b, menu.
  • Page 79 Combi Installation, Operating & Service Instructions PHTM II Troubleshooting (continued) Table 19-5: Active Fault Code and Corrective Actions (continued) Detailed Fault Code found on "b" and "c" menus in brackets, e.g. [1.0]. Code/ Possible Cause Corrective Action Name Verify system is full of water and the air has been properly purged. Cycle Air in system.
  • Page 80 Combi Installation, Operating & Service Instructions PHTM II Troubleshooting (continued) Table 19-5: Active Fault Code and Corrective Actions (continued) Detailed Fault Code found on "b" and "c" menus in brackets, e.g. [1.0]. Code/Name Possible Cause Corrective Action Check heat exchanger for excessive fouling. Clean if necessary. Heat exchanger dirty.
  • Page 81 Combi Installation, Operating & Service Instructions PHTM II Troubleshooting (continued) Table 19-5: Active Fault Code and Corrective Actions (continued) Detailed Fault Code found on "b" and "c" menus in brackets, e.g. [1.0]. Code/Name Possible Cause Corrective Action • Remove jumper from air proving switch. Defective air proving switch, •...
  • Page 82 Combi Installation, Operating & Service Instructions PHTM II Troubleshooting (continued) Table 19-5: Active Fault Code and Corrective Actions (continued) Detailed Fault Code found on "b" and "c" menus in brackets, e.g. [1.0]. Code/Name Possible Cause Corrective Action [18.0] Application parameters Normal condition following a parameter download, set Factory are not valid.
  • Page 83 Combi Installation, Operating & Service Instructions PHTM II Troubleshooting (continued) Table 19-5: Active Fault Code and Corrective Actions (continued) Detailed Fault Code found on "b" and "c" menus in brackets, e.g. [1.0]. Code/ Possible Cause Corrective Action Name [21.0], [21.2] No gas, •...
  • Page 84 Combi Installation, Operating & Service Instructions PHTM II Troubleshooting (continued) Table 19-5: Active Fault Code and Corrective Actions (continued) Detailed Fault Code found on "b" and "c" menus in brackets, e.g. [1.0]. Code/ Possible Cause Corrective Action Name No gas, insufficient gas •...
  • Page 85 Combi Installation, Operating & Service Instructions PHTM II Troubleshooting (continued) Table 19-5: Active Fault Code and Corrective Actions (continued) Detailed Fault Code found on "b" and "c" menus in brackets, e.g. [1.0]. Code/ Possible Cause Corrective Action Name [30.0] Duplicate Slave Ensure each peer-to-peer boiler has a unique slave address between 1 Boiler Addresses and 8.
  • Page 86 Combi Installation, Operating & Service Instructions PHTM II Troubleshooting (continued) Table 19-6: Detailed Fault Code (found on"c" and "b" menus) Detailed Code Type Condition Code Anti-short cycle boiler start delay, while thermostat demand present, boiler has H01.0 Warning cycled off and restart is delayed. Urgent calibration cooling delay.
  • Page 87 Combi Installation, Operating & Service Instructions PHTM II Troubleshooting (continued) Table 19-6: Detailed Fault Code (found on"c c " and "b b " menus, continued) Detailed Code Type Condition Code H17.0 Hold Internal safety core in program mode. H17.1 Hold Internal safety core error.
  • Page 88 Combi Installation, Operating & Service Instructions PHTM II Troubleshooting (continued) Table 19-6: Detailed Fault Code (found on"c c " and "b b " menus, continued) Detailed Code Type Condition Code E23.0 Lockout Flame detected before burner start. E23.1 Lockout Flame detected for 15s after gas valve closed. H23.2 Hold Defective Control: flame amplifier.
  • Page 89 Combi Installation, Operating & Service Instructions PHTM II Troubleshooting (continued) Table 19-6: Detailed Fault Code (found on"c c " and "b b " menus, continued) Detailed Code Type Condition Code H32.0 Warning Zone Panel 1 Communication Lost. H32.1 Warning Zone Panel 2 Communication Lost. H32.2 Warning Zone Panel 3 Communication Lost.
  • Page 90 Combi Installation, Operating & Service Instructions PHTM II Troubleshooting (continued) Table 19-7: Supply, DHW, Return Header and Table 19-8: Outdoor Air Temperature Sensor Flue Temperature Sensor Temperature versus Temperature versus Resistance (10 kOhm) Resistance (10 kOhm) Outdoor Temperature Ohms of Temperature Ohms of Resistance...
  • Page 91: Internal Wiring Diagrams

    Combi Installation, Operating & Service Instructions PHTM II Internal Wiring Diagrams Figure 20-1: Ladder Diagram 110331-07 - 8/23...
  • Page 92 Combi Installation, Operating & Service Instructions PHTM II Internal Wiring Diagrams (continued) Direction of flow 110331-07 - 8/23...
  • Page 93 Combi Installation, Operating & Service Instructions PHTM II Internal Wiring Diagrams (continued) 110331-07 - 8/23...
  • Page 94: Service Parts

    All service parts may be obtained through your local Velocity Boiler Works wholesale distributor. Should you require assistance in locating a Velocity Boiler Works distributor in your area, or you have questions regarding the availability of products or service parts, please contact us at (215) 535-8900 or Fax (215) 535-9736 or at www.
  • Page 95 Combi Installation, Operating & Service Instructions PHTM II Service Parts (continued) Part Number Key No. Description PHTM2136C PHTM2136CB PHTM2200C 10A, 10B, 10C, 10D, 10E, 10F, 10G Water Pipe Gaskets 110577-01 11A, 11B, 11C, 11D Water Pipes (w/ gaskets) 110578-01 111563-01 110579-01 Return Temp.
  • Page 96 Combi Installation, Operating & Service Instructions PHTM II Service Parts (continued) Part Number Key No. Description PHTM2136C PHTM2136CB PHTM2200C 23, 27, 28, 30, 50, 51, 52, Blower (with gaskets, o-rings, and 110586-01 111571-01 hardware) 24A, 24B, 24C, 24D, 24E, Gas Valve (with gaskets, o-rings, and...
  • Page 97 Combi Installation, Operating & Service Instructions PHTM II Service Parts (continued) Part Number Key No. Description PHTM2136C PHTM2136CB PHTM2200C 31A, 31B, 31C, 31D, 31E, 31F, Condensate Trap 110589-01 31G, 31H Front Door 110596-01 Vent connector 107160-01 Side panel 110725-01 111565-01...
  • Page 98 Description PHTM2136C PHTM2136CB PHTM2200C Control Enclosure 111597-01 Boiler Control 111974-01 Contact Velocity Boiler Works; Provide boiler serial number Model Key 120 VAC Connection Board 110726-01 Low Voltage Connection Board 110594-01 Fuse, 0.5A, 5 x 20 mm, 250V, Slow Blow Fuse, 1.0A, 5 x 20 mm, 250V, Slow Blow 111420-01 Fuse, 5.0A, 5 x 20 mm, 250V, Slow Blow...
  • Page 99 Combi Installation, Operating & Service Instructions PHTM II Service Parts (continued) Part Number Key No. Description PHTM2136C PHTM2136CB PHTM2200C Ignition Harness 110598-01 Main Control Harness 110599-01 Power Harness 110331-07 - 8/23...
  • Page 100: Accessories

    Combi Installation, Operating & Service Instructions PHTM II Accessories Part Number Key No. Description PHTM2136C PHTM2136CB PHTM2200C 2 in. CPVC/PVC Vent Kit Starter 107039-01 3 in. CPV/PVC Vent Kit includes vent increaser 111945-01 materials Condensate Neutralizer Kit 101867-01 Auto Reset LWCO, Hydrolevel 1100 with H5...
  • Page 101: Combination Refrigeration/Heating System

    Combi Installation, Operating & Service Instructions PHTM II Appendix A Combination Refrigeration/Heating System 1. If boiler is used in connection with refrigeration 2. If boiler is connected to heating coils located in systems, boiler must be installed with chilled air handling units where they may be exposed to medium piped in parallel with the heating boiler refrigerated air, boiler piping must be equipped using appropriate valves to prevent chilled...
  • Page 102: Water Quality And Boiler Additives

    Combi Installation, Operating & Service Instructions PHTM II Appendix B Water Quality and Boiler Additives Other non-metallic tubing is equipped with an The heat exchanger used in this boiler is made oxygen barrier to prevent migration of oxygen from stainless steel coils having relatively narrow into water.
  • Page 103: Special Requirements In Massachusetts

    Combi Installation, Operating & Service Instructions PHTM II Appendix C Special Requirements For Side-Wall Vented Appliances In The Commonwealth of Massachusetts IMPORTANT The Commonwealth of Massachusetts requires compliance with regulation 248 CMR 4.00 and 5.00 for installation of side-wall vented gas appliances as follows: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) ft.
  • Page 104 Combi Installation, Operating & Service Instructions PHTM II Appendix C Special Requirements For Side-Wall Vented Appliances In The Commonwealth of Massachusetts (continued) (c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include: 1.
  • Page 105: Code Required Text

    Combi Installation, Operating & Service Instructions PHTM II Appendix D Code Required Text See Section 5 Locating Boiler: Remove Existing Boiler 6. Une fois qu'il a été déterminé, selon la méthode indiquée ci-dessus, que chaque for context of following text: appareil raccordé...
  • Page 106 Combi Installation, Operating & Service Instructions PHTM II SERVICE RECORD DATE SERVICE PERFORMED 110331-07 - 8/23...
  • Page 107 Combi Installation, Operating & Service Instructions PHTM II SERVICE RECORD DATE SERVICE PERFORMED 110331-07 - 8/23...
  • Page 108 Combi Installation, Operating & Service Instructions PHTM II Velocity Boiler Works, LLC P.O. Box 14818 3633 I Street Philadelphia, PA 19134 110331-07 - 8/23...