Congratulations, you have purchased a product with Intelbras quality and safety. The ELC 6012 NET model is a microprocessor electrifier with two independent divisions (alarm and shock sector). The shock sector monitors the perimeter with high voltage, signaling trigger due to grounding and/or breaking the fence.
» General Personal Data Protection Law: Intelbras does not access, transfer, capture, or carry out any other type of personal data processing from this product.
Page 4
If you prefer, the battery, as well as other unused Intelbras brand electronics, can be disposed of at any collection point of Green Eletron (electronic waste manager, a company with which we are associated). If you have any...
Note: the Status TRIGGER and FENCE outputs do not allow activation by remote control. We do not guarantee the registration/operation of our electrifiers with wireless sensors that are not manufactured by Intelbras. With regard to remote controls from other manufacturers, they must have the following characteristics to work with our centers: 1.
4. Installation FENCE EARTH RETORNO BAT. Status Status INP. Output − − Trigger fence Turns on 6 7 8 9 10 11 12 1. AC: input for mains power supply; 2. F1: protection fuse 1 A (5 × 20 mm); 3. TRIGGER STATUS: fence trigger status output; 4.
Page 9
Distance 5,000 7,000 Diameter ELC 6012 NET 0.6 mm 0.9 mm Note: these values are for a maximum shock of 18,000 V, for a minimum shock of 12,000 V and a maximum distance of 1,000 meters, use a 0.6 mm cable.
Page 10
height from the ground must not exceed 3 m. This height applies to any orthogonal projection side of the outermost conductors of the electrical power line on the ground surface; for a distance of 2 m for lines operating at a nominal voltage not exceeding 1,000 V, and 15 m for electrical power lines operating at a nominal voltage exceeding 1,000 V.
Note: check if the gate board has a drive input The STATUS for trigger output can be configured as PGM and is controlled by the Intelbras APP. In this programming, the contact acts as normally open (NO), allowing external circuits to be connected as long as it does not exceed the specifications¹.
127 / 240 Vac Relay The STATUS FENCE output can be configured as PGM and is controlled by the Intelbras APP. In this programming, the contact acts as normally open (NO), allowing external circuits to be connected as long as it does not exceed the specifications¹. To activate larger loads, insert a compatible relay or contactor.
Connecting the energizer input to a button or on/off switch Electrifier Borne Connect the pair of wires from the retentive button or on/off switch to the negative terminal (-) and on input (INP. ON) of the energizer. Note: the input on, only activates the shock function. 4.3. SIREN (SIR +): maximum output = 14.5 Vdc Electrifier Borne Connect the positive (+) and negative (-) wires of the siren to the positive (SIR+) and negative (-)
4.4. LED on/off indication (LED+ OUTPUT) This output is used to view the perimeter, when the energizer is in a non-visible location. With the shock activated, it is possible to see the return of the shock in normal or triggered conditions. When the LED is off, it means the shock sector is deactivated.
4.6. Auxiliary (AUX+): Output 14.5 Vdc/250 mA This output is used to power wired sensors. Connect a wire to the positive (AUX+) and negative (-) outputs of the energizer and connect them to the positive (+) and negative (-) inputs of the sensor. It is recommended to use a wire gauge ≤...
4.8. Connecting AC power (mains) In the lower left corner of the board, there is a 2-terminal terminal (AC) to connect the control unit to the electrical network. If the fuse blows and needs to be replaced, use a fuse of the same value (1 A) with delay. To ensure greater safety for the user in case of jerks in the mains power cable, it must be installed, as shown in the following figure: 1.
Page 17
» The battery must be housed inside the electrifier box, as shown in the following image. Connect the black wire to the negative pole and the red wire to the positive pole of the battery. Red Wire Fio vermelho Polo positivo da bateria Battery positive pole Polo negativo da bateria...
» Plug the battery cable into the board's J4 connector. Battery positive pole Black wire Battery negative pole Red wire » Close and screw the lid when finished. 4.10. Connection of high-voltage cables and grounding High voltage input and grounding cables should be installed through the holes on the right side of the cabinet.
Page 19
After installing the cables, fit the electrifier cover, following the following instruction: » Instruction for fitting the cover: » Position and fit the cover to the bottom of the cabinet; » Position the cover on the top and fit the cover with the bottom until the cabinet fits;...
Page 20
» Make sure there are no gaps between the lid and the base. Place the cover fixing screws in the indicated location. Intelbras Cloud...
5. Ground connection Grounding is mandatory and very important for the sensation of shock to anyone who touches the fence wires, in addition to protection against lightning and overload of the electrical network and/or sensor wiring. Always look for a more humid place to attach the grounding rod (copper bars). The rods must be longer than 2 m, except when associated with a grounding mesh.
Assembling the rods 6. Programming via ELC 6012 NET board The ELC 6012 NET electrifier is compact and easy to program, it has several programmable para- meters that can be executed through buttons and selection jumpers directly on the board. These settings are maintained even if the electrifier is switched off completely, thus avoiding the need for frequent reprogramming.
Page 23
Homologation 0237-09-0160 (01)07896637613569 This equipment operates on a secondary basis, i.e., it is not entitled to protection against harmful in- terference, even from stations of the same type, and may not cause interference to systems operating on a primary basis. XAC 4000 Smart Control Technical specifications Activation...
Page 24
Turn off remote control Turn off remote control in Shock function 1. Keep pressing key C, the Shock and Alarm LEDs will stay on for approxima- tely 3 seconds and then go off for 3 seconds.; 2. With the LEDs off, release key C, the Shock and Alarm LEDs will flash for approximately 3 seconds indicating that all controls have been turned off.
6.2. Total reset of sensors and controls 1. Keep the keys C and S pressed, the Shock and Alarm LEDs will stay on for approximately 3 seconds and then go off for another 3 seconds. With the LEDs off, release keys C and S, the Shock and Alarm LEDs will flash for approximately 3 seconds indicating that the General Reset has been carried out.
Page 26
Note: » Maximum Sensitivity enabled (with the jumper connected): the control unit will easily detect small energy leakage points occurring along the external infrastructure, generating a siren trigger after counting 10 failed pulses. In this mode, the system presents greater safety in the activation due to perimeter rupture, even in installations where the high insulation cables have long runs and/or are not respecting the minimum distance of 2 cm between them.
Flashing fast Trigger on alarm Blinking slowly Alarm deactivated signaling previous trigger Without Wi-Fi connect module Light on Module connected to the Intelbras Cloud cloud Intelbras Cloud Blinking slowly Failed to connect to the programmed network 1 blink per second Module connected to local Wi-Fi network When powering the product solely on the battery, it takes about 1 minute to reset the Wi-Fi module.
Status LED (LD1) Status Description Wi-Fi module operating in Station mode according to the intelbras cloud LED. In programming mode. If you release the programming key while Light on the LED is on, the module enters the programming function Reset temporary master password¹. In other words, if you release...
8. Schedules via AMT Remote Mobile The ELC 6012 NET electrifier has several programmable parameters that can be executed via the AMT Remote Mobile app. These settings are maintained in the Wi-Fi connect module, thus avoiding the need for frequent reprogramming.
Page 30
» The application will fetch the Electrifier from the network created by the module itself. Note: » For the recognition of the module on the mobile device, it is necessary that the Wi-Fi of the mobile phone is enabled. ...
Page 31
» In Wi-Fi Settings, the user will be directed to their phone's Wi-Fi screen so that they can make sure that the module's network is mapped to their networks. Click on the network referring to your mo- dule and it will require the connection password which is adminadmin, then click Conect. Once this is done, the access will be validated and return to the AMT Remote Mobile application.
Page 32
» With the fields filled in, click on Connect cloud. At this moment, the Wi-Fi network is recorded in the module and the connection process to the local network and Intelbras cloud is initialized. » After the module is reset, the CLOUD LED (LD5) will be illuminated.
Page 33
Default Connection (Login) » Open the AMT Remote Mobile APP. » Enter the MAC and password of the shock control panel or scan the QR-Code, then click LOGIN. Note: MAC and passwords on the label inside the switchboard. ...
8.2. Menu (Home screen) Allows the user to Configure Central, view status through the Online tab and download events. 8.2.1Configure central Makes the main settings of the shock control unit: » General settings » Passwords/Users » Zones/Sectors » PGM ...
8.2.1.2 . Central Edit the name of the exchange using the AMT Remote Mobile application. Open AMT Remote Mobile > Menu > Configure Central > General settings > Central. 8.2.1.3 . Failed pulses Number of failed pulses needed for the fence to trigger (32 pulses). Factory default 10 pulses.
8.2.1.5 . Passwords/Users Allows you to change the names and settings of the 21 users. Open AMT Remote Mobile > Menu > Configure Central > Passwords/Users > User.
Page 38
Each user has configurable role parameters (Name and password) and their permissions. » Name: user names can be edited to a maximum of 16 characters. » Password: the password can be configured with up to 4 digits. » Bypass: allows the temporary cancellation of one or more zones. This procedure must be perfor- med within a maximum of 30 seconds before the system is activated.
8.2.1.6 . Zones/Sectors Allows you to change the names and settings of the zones. Open AMT Remote Mobile> Menu > Configure Central > Zones/Sectors > Zone. Within each zone, the user has access to its functions.
» Zone Enabled: Indicates whether the zone is enabled or disabled. » Smart Zone (Zone 1 only): this function modifies the triggering logic of the zone and is used to re- duce the possibility of a false trigger occur. If this mode of operation is enabled in zone 1, triggering will only occur under the following conditions: ...
Page 41
» Trigger status: The trigger status output is a dry contact that is triggered when there is a trigger caused by the breach of the fence or sensor perimeter. This contact acts as normally closed (NC). » Siren mirror: Normally open (NO) contact that changes to Normally Closed (NC) during the siren trigger.
8.2.1.8 . Wi-Fi Open AMT Remote Mobile > Menu > Configure Center > Wifi. » Network name: enter the name of the Wi-Fi network to be connected » Password: enter password for the Wi-Fi network to be connected ...
Page 43
Select the type of device you want, and then select REGISTER . At this point, the message will appear on the application screen for the user to activate the wireless device. It is also important that the user validates the registration by observing the ALARM and SHOCK LEDs present on the electrifier board.
Page 44
After activating the device, wait for the message Device Successfully Registered!. Note: to delete any device, see themanual 6.1. Cadastrar / apagar dispositivos sem fioitem.
8.2.2 Online Reports the status of the electrifier. » AC NETWORK: tells you if the electrifier is powered by the AC NETWORK or ON BATTERY. » Enable/Deactivate: activates or deactivates the electrifier (Alarm and/or Shock). » PGM's: activates or deactivates the electrifier's PGM's. Note: For this function, the outputs STATUS FENCE and STARUS DISP.
» Firmware: informs the Model, base board version, module version, MAC of the electrifier and check if there is an update available for the product. Note: the update must be performed with an unarmed electrifier. » Date/Time: reports the electrifier's date, time, and day of the week. 8.2.3.
Consumer regularly back up the data contained in the product. 7. Intelbras is not responsible for the installation of this product, nor for any attempts of fraud and/or sa- botage in its products. Keep the software and applications used up to date, if applicable, as well as the network protections necessary to protect against intrusions (hackers).