Download Print this page

Energizer Solar Peak 2500 User Manual page 6

Expandable battery

Advertisement

ENERGIZER SOLAR PEAK 2500
Alerting
Button Indicator Description
Red Light Blinks
Red Light Blinks
Red Light Blinks
Red Light Blinks
Red Light Blinks
Red Light Blinks
Red Light Blinks
Red Light Blinks
Red Light Blinks
Red Light Blinks
Red Light Blinks
It is recommended to restart by the switch button.
When parallelization is applied, after the battery under voltage protection and powered off, only need to press the button switch on
any battery to forcibly activate it.
Faulty
Button Indicator Description
Red Light
Constantly On
Red Light
Constantly On
Red Light
Constantly On
PAGE 05
Alerting
Over current when
discharging 1
Over current when
discharging 2
Short when discharging
Short when charging
PCB over temperature
Pre-charge resisitor over
temperature
Battery under voltage
IUIP parallel signal fault
I_WORK parallel signal
fault
Parallelization over time
Parallelization readiness
failure
Alerting
Battery voltage
sampling wire broken
MOS failure
AFE communication
failure
Solution
Restart the battery. If it's still not fixed,
contact customer service.
Restart the battery. If it's still not fixed,
contact customer service.
Turn off, remove and check equipment,
restart the battery. If it's still not fixed,
contact customer service.
Turn off, remove and check equipment,
restart the battery. If it's still not fixed,
contact customer service.
Turn off and wait for 2 hours. If it's still
not fixed, contact customer service.
Turn off and wait for 2 hours. If it's still
not fixed, contact customer service.
Charge the battery, waiting for the
voltage to recover.
Turn off, check the communication cable,
restart the battery. If it's still not fixed,
contact customer service.
Turn off, check the communication cable,
restart the battery. If it's still not fixed,
contact customer service.
Turn off, check the communication cable,
restart the battery. If it's still not fixed,
contact customer service.
Turn off, check the communication cable,
restart the battery. If it's still not fixed,
contact customer service.
Solution
Restart the battery. If it's still not fixed,
contact customer service.
Restart the battery. If it's still not fixed,
contact customer service.
Turn off, remove and check equipment,
restart the battery. If it's still not fixed,
contact customer service.
ENGLISH

Advertisement

loading