4.3.3. WIDEVINE Key Inspection
- - Confirm Key input Data at the "IN START" MENU Mode
4.4. LAN PORT INSPECTION(PING TEST)
4.4.1. Equipment setting
(1) Play the LAN Port Test PROGRAM.
(2) Input IP set up for an inspection to Test Program.
*IP Number : 12.12.2.2
SET
4.4.2. LAN PORT inspection (PING TEST)
(1) Play the LAN Port Test Program.
(2) connect each other LAN Port Jack.
(3) Play Test (F9) button and confirm OK Message.
(4) remove LAN CABLE
Copyright ©
LG Electronics. Inc. All rights reserved.
Only for training and service purposes
PC
- 16 -
4.5. Model name & Serial number
Download
4.5.1 Model name & Serial number D/L
- Press "P-ONLY" key of service remocon.
(Baud rate : 115200 bps)
- Connect RS-232C Signal to USB Cable to USB.
- Write Serial number by use USB port.
- Must check the serial number at Instart menu.
4.5.2 Method & notice
(1) Serial number D/L is using of scan equipment.
(2) Setting of scan equipment operated by Manufacturing
Technology Group.
(3) Serial number D/L must be conformed when it is produced
in production line, because serial number D/L is mandatory
by D-book 4.0
Manual Download (Model Name and Serial Number)
If the TV set is downloaded By OTA or Service man,
Sometimes model name or serial number is initialized.
(Not always)
There is impossible to download by bar code scan, so It need
Manual download.
(1) Press the 'instart' key of ADJ remote controller.
(2) Go to the menu '7.Model Number D/L' like below photo.
(3) Input the Factory model name or Serial number like photo.
(4) Check the model name Instart menu
→Factory name displayed
(5) Check the Diagnostics (DTV country only)
→Buyer model displayed
4.6. CI+ Key checking method(check the
Section 4.2) (Only EU Model)
Check whether the key was downloaded or not at 'In Start'
menu. (Refer to below).
Check the Download to CI+ Key value in LGset.
4.6.1. check the method of CI+ Key value
a. check the method on Instart menu
b. check the method of RS232C Command
1) into the main ass'y mode (RS232 : aa 00 00)
CMD 1
CMD 2
A
2) check the key download for transmitted command
(RS232 : ci 00 10)
CMD 1
CMD 2
C
I
Data 0
0
0
Data 0
1
0
LGE Internal Use Only