Sears KENMORE POWER MISER 8+ Owner's Manual page 11

Table of Contents

Advertisement

Installation
Instructions
(cont'd)
Converting the Lower
Element (cont'd)
2. The convertible
element
is located
behind the lower access
panel of the water heater. Remove the two screws securing
the access panel, and remove panel.
3. Open the flap of insulation
to expose the opening.
.
iL ,L if_ i
._,-
i;2 _t
k___J _
i,
Lower Element: Lift out the tab as shown to undip the ter-
minal cover from the thermostat.
The terminal cover can
now be removed from the thermostat.
Lift
out
tab
to
uncli_
terminal
covsr
from
thermostat_
JACKET
TERMINAL
COVER
PLASTIC
TABS ON
CLIPPED
TO THER-
BOTH
SIDES OF
MOSTAT
AT THIS
RHINAL
COVER
PO|NT
HOLD
IT IN
PLACE.
LOWER
THERMOSTAT
5. Remove the screws from terminal 2 of the element, and move
the looped end of the wire aside.
6. The buss bar is labeled 5500 W. Place the buss bar over termi-
nals 2 and 3 with the 5500 W visible. Install the extra screw
provided into terminaJ 3.
7. The wire removed from terminal 2 has a looped end. It must
remain looped and now be placed (as shown) on top of the
buss bar, over the opening of terminal 2, and secured using
the remaining screw.