0. CONTENTS However continuous improvement of our products is ADMIRAL policy. Therefore product specifications are subject to change without notice. 0. CONTENTS Readers and users are encouraged to notify 1. INTRODUCTION ADMIRAL of errors and send in suggestions for 2. SAFETY INSTRUCTIONS improvements.
3. SCOPE SAFETY INSTRUCTIONS The intended use of the LOW HANGER TUBE is to SAFETY INSTRUCTIONS: Is used for lists hang static loads at a certain, pre-determined dis- of steps, procedures or instructions that tance underneath a supporting structure. might otherwise substitute a DANGER, WARNING or CAUTION notification.
The support structure, on which the LOW HANGER TUBE is used, must have lightning protection when used outdoors. Technical data • The support structure, on which the LOW Article code: RILHT50B RILHT55B HANGER TUBE is used, might need to have electric potential bonding. EAN: 8720094420028 8720094420035 •...
LOW HANGER (Formerly known as BGI 810-3) 50 CM EN 17206:2020 Lifting and load bearing Article code: RILHT50B equipment for stages and other production areas within the entertainment industry 8 720094 420028 BS 7905-1:2001 Lifting equipment for Batchcode: HT50B-23-01...
8. ASSEMBLY INSTRUCTIONS WARNING Inspect the LOW HANGER TUBE before use. Make sure all components are in place and in good order. If damaged, mark the item clearly and take out of service*. *See chapter 11 for further instructions! Step 4 Note Secure both ends with an extra safety cable.
9. DISASSEMBLY INSTRUCTIONS 10. STORAGE The LOW HANGER TUBE must be stored in a dry, non-aggressive environment. • Make sure the parts cannot bend. • Avoid vibrations. Rubbing parts can cause excessive wear and tear. 11. MAINTENANCE & REJECTION CRITERIA Step 1 SAFETY INSTRUCTIONS Remove the safety cables from both ends.
12. WARRANTY CAUTION • When replacing parts, only use genuine For a period of 24 months we will repair, free ADMIRAL components. of charge, any damage attributable to faulty materials or workmanship under the conditi- on that the equipment is forwarded, freight •...
13. EC DECLARATION OF CONFORMITY EC-DECLARATION OF CONFORMITY FOR MACHINERY (2006/42/EG Annex II) Rolight Theatertechniek Josink Kolkweg 10 7545 PR Enschede The Netherlands Herewith declares that: ADMIRAL “LOW HANGER TUBE”; all codes starting with RILHT*** - is in compliance with the Machinery Directive 2006/42/EEC annex II - the following harmonized standards have been applied (or parts/clauses of): EN 12100-1-2010 - Part/clauses of the following technical regulations , standards and information papers have been used: German DGUV 17-18, German DGUV 215-313,...
Need help?
Do you have a question about the RILHT50B and is the answer not in the manual?
Questions and answers