Art. 4KC-1, 4KC-2, 4KC-N users
GENERAL DIRECTIONS FOR INSTALLATION
In order to achieve the best results from the schematics described it is necessary to install only original VIDEX equipment, strictly
keeping to the items indicated on each schematic and follow these General Directions for Installation:
• The system must be installed according to national rules in force, in any case the running of cables of any intercom unit must be
carried out separately from the mains (see the next paragraph for connection to mains and power supply installation);
• Use conductors with sections such as to have:
• Cables for speech line and service should have a max resistance of 10Ω
• Lock release wires and power supply wires should have a max resistance of 3Ω;
• Double check the connections before power up;
• Power up the system then check all functions.
CONNECTION TO MAINS AND POWER SUPPLY MOUNTING INSTRUCTIONS
The system must be installed according to national rules in force, in particular we recommend to:
• Connect the system to the mains through an all-pole circuit breaker which shall have contact separation of at least 3mm in each
pole and shall disconnect all poles simultaneously;
• The all-pole circuit breaker shall be placed for easy access and the switch shall remain readily operable.
POWER SUPPLY INSTALLATION
• Remove the terminal side covers by unscrewing the retaining screws;
• Fix the power supply to a DIN bar or directly to the wall using two expansion type screws;
• Switch off the mains using the circuit breaker mentioned above and then make the connections as shown on the installation diagrams;
• Check the connections and secure the wires into the terminals;
• Replace the terminal covers and fix them using the relevant screws;
• When all connections are made, restore the mains.
ATTENTION
In the event of electromagnetic fields, the performances of the production may result slightly degraded, anyway the gen-
eral operation of the system will be acceptable
LOCK RELEASE BACK EMF PROTECTION
A varistor must be fitted across the ter-
minals on AC lock release (Fig. 1) and
a diode must be fitted across the ter-
minals on a DC lock release (Fig. 2) to
suppress back EMF voltages. Connect
the components to the lock releases as
shown in figures.
CLEANING OF THE PLATE
Use a clean and soft cloth. Use moderate warm water or non-aggressive cleansers.
Do not use:
• abrasive liquids
• chlorine-based liquids
• metal cleaning products
• antioxidant products
Digiphone kit 4KC Series - Installation instructions
VARISTOR (MOV)
12V AC
LOCK RELEASE
Fig. 1
- 1 -
Digiphone kit
Fig. 2
Rev.0.2
DIODE 1N4002
12V DC
LOCK RELEASE
66250360 - V6.2 - 31/12/22

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 4KC Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Videx 4KC Series

  • Page 1 GENERAL DIRECTIONS FOR INSTALLATION In order to achieve the best results from the schematics described it is necessary to install only original VIDEX equipment, strictly keeping to the items indicated on each schematic and follow these General Directions for Installation: •...
  • Page 2: Troubleshooting Guide

    WE RECOMMEND THIS EQUIPMENT IS INSTALLED BY A COMPETENT ELECTRICIAN, SECURITY OR COMMUNICA- TIONS ENGINEER. If further assistance is required, call the technical help desk on 0191-2243174 for uk customers or +39 0734631669 for other countries. - 2 - Digiphone kit 4KC Series - Installation instructions 66250360 - V6.2 - 31/12/22...
  • Page 3: Main Features

    GENERAL DIRECTIONS FOR INSTALLATION In order to achieve the best results from the schematics described it is necessary to install only original VIDEX equipment, strictly keeping to the items indicated on each schematic and follow these General Directions for Installation: •...
  • Page 4 The exception to this is if the back light programming mode is set to Mode 2, i.e. the back light will be on full brightness all of the time or if the jumper is removed the back light will be disabled. - 4 - Digiphone kit 4KC Series - Installation instructions 66250360 - V6.2 - 31/12/22...
  • Page 5: Operation

    • metal cleaning products • antioxidant products TECHNICAL SPECIFICATION Power consumption: Standby: 20mA Operating: 70mA Working voltage: 12/24 Vac/dc Fig. 5 Fig. 6 Working temperature: -20 +60° C - 5 - Digiphone kit 4KC Series - Installation instructions 66250360 - V6.2 - 31/12/22...
  • Page 6 6 fig. 7 fig. 8 fig. 9 fig. 10 fig. 11 fig. 12 fig. 13 fig. 14 fig. 15 fig. 16 fig. 17 fig. 18 - 6 - Digiphone kit 4KC Series - Installation instructions 66250360 - V6.2 - 31/12/22...
  • Page 7 Edit the card name then replace it inside the holder and refit: insert the holder inside its housing from the left or right side then push the other side until it clips into place. - 7 - Digiphone kit 4KC Series - Installation instructions 66250360 - V6.2 - 31/12/22...
  • Page 8 Rev.0.2 NORME GENERALI D’INSTALLAZIONE Per eseguire una corretta installazione è necessario impiegare esclusivamente parti VIDEX, seguire con scrupolo quanto indicato negli schemi di collegamento e tenere presenti le norme generali d’installazione: • Realizzare gli impianti secondo le vigenti normative nazionali ed in ogni caso si consiglia di prevedere, per i conduttori dell’im- pianto, una canalizzazione distinta da quella della linea elettrica (vedi paragrafo seguente per il collegamento alla linea elettrica e l’installazione dell’alimentatore);...
  • Page 9: Caratteristiche Principali

    • LED di illuminazione tastiera. NORME GENERALI D’INSTALLAZIONE Per eseguire una corretta installazione è necessario impiegare esclusivamente parti VIDEX, seguire con scrupolo quanto indicato negli schemi di collegamento e tenere presenti le norme generali d’installazione: • Realizzare gli impianti secondo le vigenti normative nazionali ed in ogni caso si consiglia di prevedere, per i conduttori dell’im- pianto, una canalizzazione distinta da quella della linea elettrica (vedi paragrafo seguente per il collegamento alla linea elettrica e l’installazione dell’alimentatore);...
  • Page 10 Digiphone kit Serie 4KC Art. 4901 Modulo tastiera digitale AZIONAMENTO SERRATURA – PROTEZIONE DAI DISTURBI L’azionamento della serratura elettrica VARISTORE (MOV) DIODO 1N4002 può provocare degli spike, per evitare tale inconveniente si consiglia di col- legare tra i terminali della serratura un varistore (Fig.
  • Page 11: Funzionamento

    Digiphone kit Serie 4KC Art. 4901 Modulo tastiera digitale PROGRAMMAZIONE • Digitare il MASTER CODE: 6 volte 1 (111111 impostazione di DIGITARE IL Sei volte 1 “111111” fabbrica) e premere ENTER (il LED rosso si accende); “MASTER CODE” Impostazione di fabbrica •...
  • Page 12 Digiphone kit Serie 4KC Guida ai cablaggi Tutti i cablaggi devono essere passati separatamente dal cavo dell’alimentazione principale. La sezione del cavo deve essere conforme alla tabella seguente: DISTANZA IN METRI SEZIONE DEL CAVO (MM 0,22 (CAT5/CAT6 FTP/UTP/CW1308) 0,35 0,75 Resistenza massima di tutte le linee: 8 Ohm Prima di avviare il sistema, ricontrollare il cablaggio assicurandosi che sia conforme alle specifiche indicate nello schema di connessione.
  • Page 13 Digiphone kit Serie 4KC Serie 4000 Installazione posto esterno da superficie e da incasso ESEMPIO DI INSTALLAZIONE POSTO ESTERNO A 4 MODULI fig. 1 fig. 2 fig. 3 fig. 4 fig. 5 fig. 6 fig. 7 fig. 8 fig. 9 fig.
  • Page 14 Digiphone kit Serie 4KC Serie 4000 Installazione posto esterno da superficie e da incasso INSTALLAZIONE POSTO ESTERNO DA SUPERFICIE 1. Appoggiare la scatola da superficie alla parete (ci devono essere 165-170 cm tra la parte alta della scatola e il terreno come mostrato in Fig.1) e prendere i riferimenti per i fori di fissaggio tenendo conto che il gruppo di fili (Fig.
  • Page 15 - 15 - 66250360 - V6.2 - 31/12/22...
  • Page 16 - 16 - 66250360 - V6.2 - 31/12/22...
  • Page 17 - 17 - 66250360 - V6.2 - 31/12/22...
  • Page 18 - 18 - 66250360 - V6.2 - 31/12/22...
  • Page 19 DISPOSAL In accordance with the Legislative Decree no. 49 of 14 March 2014 “Implementation of the Directive 2012/19/EU on waste electrical and electronic equipment (WEEE)”. The crossed-out bin symbol on the equipment or on the packaging indicates that when the product reaches the end of its lifetime, it must be collected separately from mixed municipal waste.
  • Page 20 APOIO AO CLIENTE ‫خدمة العمالء‬ Portugal office: Singapore office: VX IBÉRIA, UNIPESSOAL LDA VIDEX ASIA PACIFIC PTE LTD Rua Tenente Mário Grilo, 26 D, E, F 1 TAMPINES NORTH DRIVE 1, 4200-397 Porto #06-08, T-Space Phone: (+351) 221 124 531 Singapore 528559 www.videx.it...

This manual is also suitable for:

4kc-14kc-24kc-n

Table of Contents