note 1
2.1.2
Storage
Temperature range
Humidity range
note 2
2.1.3
Altitude
Operating
Storage
Note 1: Temperature and relative humidity range must be in the area shown as the following figure due to
panel limited
Note 2: Altitude spec must not over panel spec.
2.2 Safety, EMC, Ergonomics and Compatibility Requirements
Safety & EMC
Ergonomics
Compatibility
Power Management
2.3 Electrostatic Discharge Requirements
The subject unit must withstand ±8KV for contact discharge and ±15KV for air discharge of Electrostatic Discharge
and meet the standard of IEC61000-4-2(EN55024).
Item
Electrostatic
Discharge
2.4 Reliability
The MTBF of this product shall be greater than 50,000 hours excluding the LCD panel. The LCD panel life which is
defined as the time period for the maximum luminance to reduce to 50% of the initial value is 40,000 hours minimum at
the condition of displaying an all WHITE field at mid Brightness and Contrast settings.
3. Electrical and Optical Characteristics and Performance
:
: -20°C to 60°C
: 10% to 90%
40000 ft (Ta=30, t=24h )
Figure 1 Absolute Ratings of Environment
UL/ cUL, CE, CB, CCC, Nemko/Ergo, C-Tick (N214), VCCI,
FCC, CCC, BSMI,
Nemko/Ergo,MPR II,ISO13460-2,TCO99,TCO03
Windows 98/Me/2000, Windows XP, Window Vista
Energy Star V4
Condition
Acer SPEC
10000 ft (Ta=50, t=24h)
(without discharge on VGA/DVI/HDMI pin)
Spec
Contact discharge : +/-4KV
Contact discharge : +/-8KV
Air discharge : +/-8KV
Air discharge : +/-15KV
Acer –LCD-G205H
Remark
150pF/330ohm.
Each point 10
times.
1 time/Sec.