6.2 Precision adjustment
The equipment has a depth setting adjuster
(Fig. 6/Item G) in the form of a knurled screw.
If you screw it downwards (Fig. 6/Item 1), the
staples/nails will be shot in deeper.
If you want to reduce the depth that the stap-
les/nails are shot in, you have to screw the
knurled screw upwards (Fig. 6/Item 2).
Danger! To prevent triggering unintentionally, the
depth setting must never be pulled back by hand
in normal operation.
7. Cleaning, maintenance and
ordering of spare parts
Disconnect the compressed air supply from the
equipment before performing any cleaning work.
7.1 Cleaning
Keep all safety devices, air vents and the
motor housing free of dirt and dust as far as
possible. Wipe the equipment with a clean
cloth or blow it down with compressed air at
low pressure.
We recommend cleaning the equipment im-
mediately each time after use.
Clean the equipment regularly with a damp
cloth and some soft soap. Do not use
cleaning agents or solvents; these may be ag-
gressive to the plastic parts in the equipment.
Ensure that no water can get into the interior
of the equipment.
7.2 Maintenance
Warning!
Disconnect the equipment from the compressed
air supply before you carry out any maintenance
or cleaning work.
Compliance with the maintenance instructions lis-
ted here will help this quality product provide you
with a long service life and trouble-free operation.
Regular lubrication is essential for your equip-
ment to work properly for a prolonged period of
time.
Regularly check the speed and the vibration level
by simply observing the tool.
Note: Use environmentally friendly compressed
air oil if you want to operate the equipment out-
side the workshop.
Anl_TC_PN_50_GB_Korea.indb 11
Anl_TC_PN_50_GB_Korea.indb 11
GB
The following lubrication options are available:
Lubrication by mist oiler
Connect a mist oiler between the compressed air
source and the equipment (not supplied, available
at retail stores)
By hand
Each time before using the compressed air tool
insert 3-5 drops of special compressed air oil
into the compressed air connection. If the com-
pressed air tool has not been used for several
days you must insert 5-10 drops of special com-
pressed air oil into the compressed air connection
before switching on.
Store your compressed air tool only in a dry room.
Other maintenance
There are no other parts inside the equipment
which require maintenance.
Excluded from the guarantee are:
Wear parts
Damage cause by too much operating pres-
sure.
Damage caused by non-conditioned com-
pressed air.
Damage caused by improper use or unautho-
rized intervention.
7.3 Ordering replacement parts:
Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.Einhell-Service.com

8. Disposal and recycling

The equipment is supplied in packaging to pre-
vent it from being damaged in transit. The raw
materials in this packaging can be reused or
recycled. The equipment and its accessories are
made of various types of material, such as metal
and plastic. Never place defective equipment in
your household refuse. The equipment should
be taken to a suitable collection center for proper
disposal. If you do not know the whereabouts of
such a collection point, you should ask in your
local council offi ces.
- 11 -