Temperature controller Evco

Error messages and error correction

Error mes-
Problem
sage
Lower temperature alarm
AL1
(at sensor 1)
Lower temperature alarm
AL2
(at sensor 2)*
AH
Upper temperature alarm
Door switch input alarm
id
(only if parameter i0 has
the value 2 or 3)
Multipurpose input alarm
iA
(only if parameter i0 has
the value 0)
"Device locked" alarm
iSd
(only if parameter i0 has
the value 0)
The copying process of
the parameter set from the
ESt
device to the programming
key (upload) has failed.
The firmware on the de-
CEr
vices do not match
The copying process of
the parameter set from
Erd
the programming key to
the device (download) has
failed.
Pr1
Error at sensor 1
Pr2
Error at sensor 2*
Pr3
Error at sensor 3*
* only relevant if the device is prepared for 2 to 3 sensors
Remedy
- Check actual temperature
- Look at parameters A1 and A3
- Check actual temperature
- Look at parameters A5 and A7
- Check actual temperature
- Look at parameters A5, A6 and A5
- Check the reasons that have provoked the
activation of the input
- Look at parameters i0 and i1
- Check the reasons that have provoked the
activation of the input
- Look at parameters i1 and i5 (if parameter i5 =
value 3, there will be no effect; if parameter i5 =
value 4, the compressor will be turned off)
- Check the reasons that have provoked the
activation of the multipurpose input
- Switch device on/off
- Look at parameters i1, i5, i7, i8 and i9
- Press any button to restore normal operation
and switch off the buzzer
- Check the connection between the device and
the programming key
- Check whether the programming key is working
correctly
- Repeat the copying process
- Check the agreement of the firmware versions
(check manufacturing date)
- If necessary, replace device
- Press any button to restore normal operation
and switch off the buzzer
- Unplug/plug in the device
- Check the connection between the device and
the programming key
- Check whether the programming key is working
correctly
- Repeat the copying process
- Restore the default setting for the parameter
configuration
- Look at parameter P0
- Check whether the sensor (1/2/3) is working
correctly
- Check the connection between the device and
the sensor
- Check actual temperature
en