Temperature controller Evco
Configuring the setup parameters
The setup parameters should only be changed under unfavorable operating conditions. The set-
tings may only be configured as expressly instructed by Franke Foodservice Systems.
set
- Briefly press
: SEt will appear.
- Press
or
until PA appears on the display.
- Select the menu item using
- Press and hold
until the number 72 appears on the display. While
numerical value of 0 is incremented until the button is released.
set
- Confirm with
: The first parameter is displayed.
- Use
to set the value of the first parameter.
set
- Confirm with
: The second parameter is displayed.
- Repeat the procedure to set all parameters.
- Wait 20 seconds to exit the menu.
Restoring the factory settings
In the event of a fault, the factory settings should be restored first.
set
- Press and hold
and
The reset is complete.

Screen messages

Message
Meaning
Loc
Keyboard or active set point is locked.
The quantity to be displayed is not available (example: because the tempera-
- - - -
ture sensor has not been activated)
Display flashes:
Cln
Access to the copying process for the parameter set has been created.
Data output from the device is switched off.
Display flashes:
Decision made to continue with the copying of the parameter set from the
device to the programming key (upload)
Data output from the device is switched off.
St
Display is permanently lit
The copying process from the device to the programming key (upload) is ongo-
ing.
Data output from the device is switched off.
The copying process from the programming key to the device (download) has
PrG
been successfully concluded (press any button so that the "PrG" display disap-
pears). The device will restore normal operation.
set
.
simultaneously for 8 seconds until dEF flashes on the display.