Specifications
Video signal
Color system
NTSC, PAL, SECAM, NTSC4.43
Resolution
500 TV lines
Frequency response
LINE
6 MHz+3dB (Y signal)
RGB
(PVM-14N1A/14N1E/14N10/14N2A/14N2E/14N2U/
20N 1 A/20N 1E/20N 1U/20N2A/20N2E/20N2U ONLY)
6 MHz+3dB
Picture performance
Normal scan
7 % over scan of CRT effective screen
area
H. linearity
Less than 8.0 % (typical)
V. linearity
Less than 7.0 % (typical)
CRT
P22 phosphor
Color temperature
6,500 K
inputs
LINE A/B (PVM-14N1A/14N1E/14NIMDE/14N1U/14N2A/
14N2E/14N2U/20N 1 A/20N 1 E/20N 1 U/20N2A/20N2E/
20N2U ONLY)
Y/C IN
4-pin mini-DIN(x2)
See the pin assignment on the next page.
VIDEO IN
BNC connector (x2), 1 Vp-p +3 dB, -6
dB, sync negative
AUDIO IN
Phono jack (x2), —-5 dBu®, more than 47
kilo-ohms
LINE (SSM-14N1 A/14N1E/14N1U/20N1A/20N1E/20N1U
ONLY)
Y/C IN
4-pin mini-DIN(x1)
See the pin assignment on this page.
VIDEO IN
BNC connector (x1), | Vp-p+3 dB,
—6 dB, sync negative
AUDIO IN _ Phono jack (x1), -5 dBua), more than 47
kilo-ohms
RGB (PVM-14N2A/14N2E/14N2U/20N2A/20N2E/20N2U
only)
R/G/B BNC connector (x3)
0.7 Vp-p +3 dB, -6 dB
Sync on green: 0.3 Vp-p, negative,
Automatic 75 ohms termination
Phono jack (x1), -5 dBu®, more than 47
kilo-ohms
BNC connector (x1)
4 Vp-p +3 dB, —6 dB, sync negative
AUDIO IN
EXT SYNC
REMOTE
(PVM-14N2A/14N2E/14N2U/20N2A/20N2E/
-20N2U only)
Phono jack (X1)
Open: currently selected input
signal
Low state (GND): input signal
selected prior to the current
input signal
a) O dBu = 0.775 Vr.m.s.
Outputs
LINE A
Y/C OUT
— 4-pin mim-DIN (x1) loop-through,
Automatic 75 ohms termination
VIDEO OUT
BNC connector (x1) loop-through,
Automatic 75 ohms termination
AUDIO OUT
Speaker output
General
(PVM-I14N1MDE only)
Classification of equipment
— Type of protection against electric shock:
Class I equipment
* Standard evaluated to:
Phono jack (x1) loop-through
Output level: 0.8 W
EN 60 601
CSA C22.2 No,601.1
UL 2601-1
—Degree of protection against harmful ingress of water:
Ordinary equipment
— Degree of safety of application in the presence of a
flammable anaesthetic mixture:
Not protected equipment
— Mode of operation:
Continuous operation
— Information concerning type and frequency of technical
maintenance:
Not need maintenance equipment
— Main power switch:
CRT
Power consumption
Power requirements
Functional switch
14-inch CRT with P-22
phosphor
Visible picture size 332 mm
(13-inch measured diagonally)
PVM-I4N1A/14N1E/14N1MDE/
14N1U/SSM-14N1TA/14N1E/
14N1U: 80W
PVM-14N2A/14N2E/14N2U: 80W
PVM-20N1U/20N2U/
SSM-20N1U: 100W
PVM-20N1 A/20N2A/20N 1E/
20N2E/SSM-20N
1 A/20N1E: 105 W
100 to 240 V AC, 50/60Hz
"For use of PVM-14N1U/14N2U/
20N1U/20N2U/SSM-14N1U/20N1U",
operate these monitors on 120 V AC.
1.2-0.6A (PVM-14NIMDE)
Operating temperature
PVM-I4NIA/I4NIE/I4N1U/14N2A/
14N2E/14N2U/20N 1 A/20N 1E/
20N 1U/20N2A/20N2E/20N2U,
SSM-14N1A/14N1E/14N1U/20N1 A/
20N1E/20N1U
(0 to +35°C (32 to 95°F)
PVM-14N1MDE:0 to +40°C (32 to
104°F)